Patient triggered ventilation

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neonatal patient triggered ventilation.

Patient triggered ventilation was assessed in 14 neonates (gestational age 24-40 weeks). Inspiratory changes in airflow, monitored by a pneumotachograph, were used to trigger the ventilator and this was not associated with complications. Patient triggered ventilation was maintained for up to eight hours (mean duration five hours). In 13 of 14 infants oxygenation improved and this was associated...

متن کامل

Patient triggered ventilation using a flow triggered system.

The role of patient triggered ventilation (PTV) for the newborn was assessed using a new patient triggered ventilator, the Draeger Bablylog 8000, which incorporates significant improvements in both ventilator performance and the triggering system. Thirty three infants, median gestational age 30 weeks and postnatal age 2.5 days, were entered into the study to compare blood gases obtained during ...

متن کامل

Limitations of patient triggered ventilation in neonates.

The practicality of long term patient triggered ventilation using airflow changes was assessed in 22 infants with a median gestational age of 29 weeks (range 25-33 weeks). Inflation time during patient triggered ventilation was limited to 0.4 seconds or less. Initially it was associated with improvements in oxygenation in most infants. Patient triggered ventilation was maintained till final ext...

متن کامل

Patient triggered ventilation in premature neonates

Patient triggered ventilation using oesophageal pressure changes was assessed in eight premature neonates. Respiratory activity was reliably recorded and positive pressure inflation occurred synchronously with inspiration. Peristalsis resulted in only minimal interference. During patient triggered ventilation, inflating volume and oxygenation increased significantly compared with periods of con...

متن کامل

Comparison of triggering systems for neonatal patient triggered ventilation.

The efficacy of two triggering systems was compared during neonatal patient triggered ventilation: the Graseby MR10 respiration monitor and airway pressure changes. Ten preterm infants were studied, median gestational age 33 weeks (range 28-35). Patient triggered ventilation was administered via the SLE ventilator at a series of inflation times (0.24, 0.3, and 0.4 seconds). Comparison was made ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Archives of Disease in Childhood - Fetal and Neonatal Edition

سال: 2000

ISSN: 1359-2998

DOI: 10.1136/fn.83.3.f224c