BACKGROUND Pedicle screw instrumentation is widely used for spinal stabilization. However, the accuracy for free-hand screw placement ranges from 69% to 94%. This study assesses the value of the existing classification systems, and investigates their impact on the ability to assess the accuracy of free-hand screw placement. METHODS Data were collected retrospectively from the medical records ...

متن کامل

Pedicle screw placement accuracy of bone-mounted miniature robot system

This article describes factors affecting the accuracy of transpedicle screw placements performed with the Renaissance robot-guided system and reviews the relevant literature. Between January 2013 and January 2015, Renaissance robot-guided spinal surgery was performed in 125 patients at Kaohsiung Medical University Hospital in Kaohsiung, Taiwan. The surgeries included 662 transpedicle screw impl...

متن کامل

Accuracy of pedicle screw placement in patients with Marfan syndrome

BACKGROUND There is no study concerning safety and accuracy of pedicle screw placement in Marfan syndrome. The objective of this study is to investigate accuracy and safety of pedicle screw placement in scoliosis associated with Marfan syndrome. METHODS CT scanning was performed to analyze accuracy of pedicle screw placement. Pedicle perforations were classified as medial, lateral or anterior...

متن کامل

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

Comparison of Cranial Facet Joint Violation Rate Between Percutaneous and Open Pedicle Screw Placement

Percutaneous and open pedicle screw placements have been widely used in lumbar fusion surgery. However, there are conflicting reports of cranial facet joint violation rate for the 2 techniques. To better determine the rate of cranial facet joint violation, a systematic review and meta-analysis was performed in the present study. We searched the established electronic literature databases includ...