Penning transfer in argon-based gas mixtures
نویسندگان
چکیده
منابع مشابه
Drift velocity and gain in argon- and xenon-based mixtures
We present measurements of drift velocities and gains in gas mixtures based on Ar and Xe, with CO2, CH4, and N2 as quenchers, and compare them with calculations. In particular, we show the dependence of Arand Xe-CO2 drift velocities and gains on the amount of nitrogen contamination in the gas, which in real experiments may build up through leaks. A quantification of the Penning mechanism which ...
متن کاملStandardisation of gas mixtures for estimating carbon monoxide transfer factor.
BACKGROUND The American Thoracic Society recommends that the inspired concentration used for the estimation of carbon monoxide transfer factor (TLCO) mixture should be 0.25-0.35% carbon monoxide, 10-14% helium, 17-21% oxygen, balance nitrogen. Inspired oxygen influences alveolar oxygen and hence carbon monoxide uptake, such that transfer factor increases by 0.35% per mm Hg decrease in alveolar ...
متن کاملExperimental determination of the Townsend coefficient for Argon-CO2 gas mixtures at high fields
The first Townsend coefficient for Ar-CO 2 based gas mixtures has been measured over a wide range of reduced electric field. The experimental setup and the measurement technique are described here. A linear superposition model has also been successfully applied.
متن کاملExperimental Investigation in Pool Boiling Heat Transfer of Pure/Binary Mixtures and Heat Transfer Correlations
Nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. Measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. In this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in p...
متن کاملAnaesthetic Mixtures: Gas Chromatography
acids and peptides due to the manifold separation modes that can be applied. Short analysis times, easy manipulation of separation conditions and small injection volumes (nanolitres) are further advantages. The Reld of biomedical and clinical amino acid and peptide analysis is still under investigation, especially as the transfer and adaptation of the separation modes to a broader range of real...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Instrumentation
سال: 2010
ISSN: 1748-0221
DOI: 10.1088/1748-0221/5/05/p05002