Performance Analysis of A Single Stage Absorption Cooling System at Different Operating Temperatures
نویسندگان
چکیده
Today, rapid developments are experienced in terms of energy consumption and efficiency air conditioning systems. Among these systems, waste heat renewable sources used absorption cooling Although the initial investment cost this system is high, operating low due to use heat. In study, effect generator, condenser, absorber evaporator temperatures on performance (COP) systems with single-stage LiBr-H_2 O fluid pair was investigated. The temperature investigated using balances help thermodynamic equations. It found from results that increased increasing generator temperature, decreased condenser temperatures. addition, it determined solution concentration changed examined at different temperatures, crystallization occurred accordingly some parameters.
منابع مشابه
Optimization of Solar Absorption Cooling System Considering Hourly Analysis
Thermal modelling and optimal design of a solar absorption cooling system are presented, and hourly analysis is performed over the period of a year. Three design parameters are considered, then the Real Parameter Genetic Algorithm (RPGA) is applied to obtain the minimum total annual cost. The optimization results show that the solar cooling optimum configuration needs 1630 square meter collecto...
متن کاملthe role of application of dynamic assessment approach in improvement of iranian efl writing performance at different language proficiency levels
the present study sought to investigate the role of dynamic assessment (da) in improvement of iranian efl writing performance at different language proficiency levels. to this end, after conducting the quick placement test, 60 iranian efl learners were assigned to two groups with different language proficiency levels. in both groups each participant wrote two compositions, one before and one af...
Coefficient of Performance Optimization of a Single Stage Thermoelectric Cooler
In thermoelectric coolers (TECs) applied external voltage potential is generated to a temperature difference based on the Peltier effect. Main and basic structure of TECs is in the form of single stage device. Due to the low efficiency, especially low coefficient of performance (COP) of thermoelectric coolers, optimal design of geometrical parameters of such devices is vital. For this purpose, ...
متن کاملStudy of the performance of a solar adsorption cooling system
This article presents a transient model of a solar adsorption cooling system. A computer program has been developed to simulate the operation of a two bed silica gel- water adsorption cooling system as well as flat plate collectors and the hot water storage tank. This program is then utilized to simulate the performance of a sample solar adsorption cooling system used for cooling a set of r...
متن کاملThermoeconomic analysis of a hybrid PVT solar system integrated with double effect absorption chiller for cooling/hydrogen production
A novel solar-based combined system which is consisting of a concentrated PV, a double effect LiBr-H2O absorption chiller, and a Proton Exchange Membrane (PEM) is proposed for hydrogen production. A portion of the received energy is recovered to run a double effect absorption chiller and the rest is turned into electricity, being consumed in the PEM electrolyzer for hydrogen producti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Osmaniye Korkut Ata Üniversitesi Fen Bilimleri Enstitüsü dergisi
سال: 2022
ISSN: ['2687-3729']
DOI: https://doi.org/10.47495/okufbed.1037524