Performance analysis of shunt active filter for harmonic compensation under various non-linear loads
نویسندگان
چکیده
منابع مشابه
Power System Harmonic Compensation Using Shunt Active Power Filter
This paper shows the method of improving the power quality using shunt active power filter. The proposedtopic comprises of PI controller, filter hysteresis current control loop, dc link capacitor. The switching signal generation for filter is fromhysteresis current controller techniques. With the all these element shunt active power filter reduce the total harmonic distortion. Thispaper represe...
متن کاملHigh Performance Seven Level Active Shunt Filter for Harmonic Mitigation
This paper deals with the simulation of a shunt active filter using seven level cascaded H-bridge multilevel inverter. The proposed active filter topology can also produce seven voltage levels, which significantly reduces the switching current ripple and the size of passive components. The seven level active shunt filter provides compensation of load power factor and current harmonics. For comp...
متن کاملAnalysis, Dimensioning and Robust Control of Shunt Active Filter for Harmonic Currents Compensation in Electrical Mains
In this chapter some results related to Shunt Active Filters (SAFs) and obtained by the authors and some coauthors are reported. SAFs are complex power electronics equipments adopted to compensate for current harmonic pollution in electric mains, due to nonlinear loads. By using a proper "floating" capacitor as energy reservoir, the SAF purpose is to inject in the line grid currents canceling t...
متن کاملApplication of a Shunt Active Power Filter to Compensate Multiple Non-linear Loads
In this paper, the implementation of a shunt active power filter with a small series reactor for a three-phase system is presented. The system consists of multiple non-linear loads, which are a combination of harmonic current sources and harmonic voltage sources, with significant unbalanced components. The filter consists of a three-phase current-controlled voltage source inverter (CC-VSI) with...
متن کاملIndirect Control of Single-Phase Active Power Filters using Harmonic Control Arrays
The ever increase of nonlinear loads in electric distribution networks causes many problems due to the high level of harmonic currents. This paper proposes a new technique for controlling a single phase shunt active power filter based on a selective compensation using the newly developed technique of harmonic control arrays. Simulation results confirm the appropriate selective harmonic compensa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Emerging Electric Power Systems
سال: 2020
ISSN: 1553-779X,2194-5756
DOI: 10.1515/ijeeps-2020-0197