Performance analysis of vapor compression refrigeration system using mixed refrigerant R410A

نویسندگان

چکیده

Mixed refrigerants are obtained from mixing pure in specific proportions and it is known as mixed refrigerants. Mixture divided into two groups according to their thermodynamic behavior: zeotropic mixtures azeotropic mixtures. In this study, the performance of R410A refrigerant mixture (R125 R32) vapor compression refrigeration cycle was investigated. The coefficients (COP) cooling system under different operating conditions were highest COP value for working study determined 7.3. addition, capacity compressor has been conditions.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Refrigerant Charge over the Performance Characteristics of a Simple Vapour Compression Refrigeration System

Experimental investigation was done to find the role of capillary tube length and amount of refrigerant charge on the overall heat transfer coefficient in condenser and evaporator and actual COP of a simple vapour compression refrigeration system. It was concluded that increasing of the refrigerant charge in the system largely enhances the overall heat transfer coefficient in the evaporator by ...

متن کامل

Comparative Exergy Analysis of Vapor Compression Refrigeration System Using Alternative Refrigerants

Abstract—In present paper, the performance of various alternative refrigerants is compared to find the substitute of R22, the widely used hydrochlorofluorocarbon refrigerant in developing countries. These include the environmentally friendly hydrofluorocarbon (HFC) refrigerants such as R134A, R410A, R407C and M20. In the present study, a steady state thermodynamic model (includes both first and...

متن کامل

Reduced CFC Refrigerant Emission By a Modified Vapor Compression Refrigeration Cycle

This paper describes a modification of vapor compression cycles with a novel Heat-Mass-Exchange (HME) technique. The HME unit reduces irreversibilities by utilizing the heat generated in the compressor to pump a portion of the refrigerant. It also allows the utilization of low grade heat sources (say, at 100°C) to supply a portion of the required thermodynamic work. Calculations indicate that e...

متن کامل

Using Carbon Dioxide in a Transcritical Vapor Compression Refrigeration Cycle

For most of the last fifty years, refrigeration and heat pump systems have been based on cycles using a fluorocarbon as the working fluid. Hovvever, with the discovery that fluorocarbons may have a profoundly detrimental effect on the earth ·s atmosphere. it has become necessary to find a suitable replacement for a fluorocarbon based refrigeration cycle. Such a replacement must perform comparab...

متن کامل

Thermodynamic analysis of vapour compression refrigeration system using alternative refrigerants

This research is aimed to define , (1) the effects of refrigerant to the environment, (2) derive the eco friendly refrigerants by using software REFPROP, (3) describe the properties of refrigerant by mixing them in appropriate percentage, (4) reducing GWP and ODP by providing suitable substitute of CFC’s and HCFC’s refrigerants, (5) reducing the effect of refrigerant to the ODP. This analysis i...

متن کامل