Performance Characteristics of the COBAS AMPLICOR Hepatitis C Virus MONITOR Test, Version 2.0
نویسندگان
چکیده
منابع مشابه
Clinical evaluation of the automated COBAS AMPLICOR HCV MONITOR test version 2.0 for quantifying serum hepatitis C virus RNA and comparison to the quantiplex HCV version 2.0 test.
A second-generation hepatitis C virus (HCV) quantitative assay (COBAS AMPLICOR HCV MONITOR Test, version 2.0; COBAS HCM-2) has been developed, with the intention of achieving equivalent quantification of all HCV genotypes and improving assay performance. To evaluate the clinical performance of COBAS HCM-2 and its utility in predicting the response to alpha interferon treatment, sera from 215 ch...
متن کاملPerformance characteristics of the COBAS Amplicor Hepatitis C Virus (HCV) Monitor, Version 2.0, International Unit assay and the National Genetics Institute HCV Superquant assay.
The COBAS Amplicor Hepatitis C Virus (HCV) Monitor assay, version 2.0, which reports in international units per milliliter, was compared to the assay reported in copies per milliliter by analyzing dilution series and clinical plasma samples by both methods. In addition, the Amplicor international unit assay was compared to the National Genetics Institute HCV Superquant assay. The dilution serie...
متن کاملPerformance of the COBAS AMPLICOR HCV MONITOR test, version 2.0, an automated reverse transcription-PCR quantitative system for hepatitis C virus load determination.
A clinical evaluation of an automated quantitative PCR assay, the COBAS AMPLICOR HCV MONITOR test, version 2.0 (v2.0), was carried out to assess the performance of this test in comparison with that of the previous, manual version, the AMPLICOR HCV MONITOR test, and with that of nested PCR. Serial dilutions of serum samples infected with genotype 1b, 2a, or 3, as well as synthetic RNA transcript...
متن کاملOverestimation of the hepatitis C virus RNA content of reference preparations by the AMPLICOR HCV monitor test, version 2.0.
An evaluation of the AMPLICOR hepatitis C virus (HCV) monitor test, version 2.0 (Roche Diagnostics), was carried out to investigate whether this test overestimates the HCV RNA content of reference preparations. Satisfactory accuracy was observed when the World Health Organization HCV international standard was included in the assay and a modified formula was used to calculate the viral content.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: American Journal of Clinical Pathology
سال: 2000
ISSN: 1943-7722,0002-9173
DOI: 10.1309/kajf-dl9g-0pnb-0fyh