Performance evaluation of KHU Mark2 parallel multi-frequency EIT system

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-frequency EIT system with radially symmetric architecture: KHU Mark1.

We describe the development of a multi-frequency electrical impedance tomography (EIT) system (KHU Mark1) with a single balanced current source and multiple voltmeters. It was primarily designed for imaging brain function with a flexible strategy for addressing electrodes and a frequency range from 10 Hz-500 kHz. The maximal number of voltmeters is 64, and all of them can simultaneously acquire...

متن کامل

Evaluation of EIT system performance.

An electrical impedance tomography (EIT) system images internal conductivity from surface electrical stimulation and measurement. Such systems necessarily comprise multiple design choices from cables and hardware design to calibration and image reconstruction. In order to compare EIT systems and study the consequences of changes in system performance, this paper describes a systematic approach ...

متن کامل

Calibration methods for a multi-channel multi-frequency EIT system.

Multi-channel multi-frequency electrical impedance tomography (EIT) systems require a careful calibration to minimize systematic errors. We describe novel calibration methods for the recently developed KHU Mark1 EIT system. Current source calibration includes maximization of output resistance and minimization of output capacitance using multiple generalized impedance converters. Phase and gain ...

متن کامل

Optimized electrode positions and stimulation patterns in head EIT

Electrical Impedance Tomography (EIT) has potential for imaging of the head to image cerebral edema and stroke, and to assist the EEG inverse problem. One key challenge is the low distinguishability of head EIT. In this paper, we develop a strategy to improve distinguishability by optimizing electrode configurations and stimulation and measurement patterns. In a hemispherical simulation phantom...

متن کامل

Electrical impedance imaging system using FPGAs for flexibility and interoperability

BACKGROUND Modern EIT systems require simultaneously operating multiple functions for flexibility, interoperability, and clinical applicability. To implement versatile functions, expandable design and implementation tools are needed. On the other hand, it is necessary to develop an ASIC-based EIT system to maximize its performance. Since the ASIC design is expensive and unchangeable, we can use...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2010

ISSN: 1742-6596

DOI: 10.1088/1742-6596/224/1/012013