Performance evaluation of PV penetration at different locations in a LV distribution network connected with an off-load tap changing transformer

نویسندگان

چکیده

<span>Solar photovoltaic (PV) power generation has shown a worldwide remarkable growth in recent years. In order to achieve the increasing energy demand, large number of residential PV units are connected low voltage (LV) distribution networks. However, high integration solar could cause negative impacts on grids leading violations limits and standards. The rise been recognized as one major implications increased integration, which significantly restrict capacity network support higher penetration levels. This study addresses performance off-load tap changing transformer under detailed analysis carried out examine maximum allowable at discrete positions transformer. determined by ensuring that all nodal voltages adhere grid statutory limits. simulation results demonstrate first two be adopted control penetrations thus facilitating further influx into existing network.</span>

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Solid-State on Load Distribution Transformer Tap-Changer on Power Quality Enhancement

Recently electronic tap-changer has received more attention due to its quick response, better performance and simpler maintenance compared to the mechanical tap-changer. This paper presents the capability of the distribution transformer equipped with an electronic tap-changer for improving power quality. At this end, the analytical computation for determining the compensating limit of electroni...

متن کامل

A Grid-Connected PV Inverter with Compensation of Load Active and Reactive Power Imbalance for Distribution Networks

Load balancing is an important issue in distributed systems. In addition, using distributed generation sources such as photovoltaic is increasing. Power electronic converters are main interfaces between the sources and the grid. In this paper, a method has been proposed to reduce the load imbalancing in distribution networks using PV Grid Interface Converter. Two DC/DC and DC/AC converters have...

متن کامل

the role of application of dynamic assessment approach in improvement of iranian efl writing performance at different language proficiency levels

the present study sought to investigate the role of dynamic assessment (da) in improvement of iranian efl writing performance at different language proficiency levels. to this end, after conducting the quick placement test, 60 iranian efl learners were assigned to two groups with different language proficiency levels. in both groups each participant wrote two compositions, one before and one af...

Load Tap Changing Control

The control used for the tapchanger of an LTC transformer or step-voltage regulator is a prime illustration of electronic technology advances applied to the power industry. Electro-mechanical (balance-beam and induction disc), discrete static, integrated circuit static and now digital designs have evolved over the past forty years. This increased product sophistication has made possible many fe...

متن کامل

Transformer voltage control and Tap changing

The voltage control is performed by changing the turns ratio. This is done by provision of taps in the winding. The volts per turn available in large transformers is quite high and hence a change of even one turn on the LV side represents a large percentage change in the voltage. Also the LV currents are normally too large to take out the tapping from the windings. LV winding being the inner wi...