منابع مشابه

Performance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel

Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...

متن کامل

Effect of column-foundation connection stiffness on seismic performance of rocking steel braced frame

Residual drifts after severe earthquakes interrupt serviceability of buildings. Retrofitting of such buildings is in many cases very difficult and consumes lots of time and money. Recently, there are some attempts to develop the seismic design procedures to not only satisfy life safety criteria but also lead to more economical buildings. One of these modern methods of improving seismic performa...

متن کامل

Nonlinear Numerical Analyses of a Fabricated Connection of Concrete-Filled Steel Column to Steel Beam Under Low-Reversed Cyclic Loading

RESEARCH ARTICLE Nonlinear Numerical Analyses of a Fabricated Connection of Concrete-Filled Steel Column to Steel Beam Under Low-Reversed Cyclic Loading Chunyi Cui, Kun Meng, Yan Kong, Yannian Zhang and Wenxin Zuo Department of Civil Engineering, Dalian Maritime University, Dalian 116026, China School of Civil Engineering, Shenyang Jianzhu University, Shenyang 110168, China School of Civil and ...

متن کامل

Evaluation of Column-Tree Moment Resisting Connection with End Plates and Haunched Beam (RESEARCH NOTE)

The column-tree constructional schemes allows for a reliable and convenient erection of moment resisting steel frames. Strengthening of column-tree connection with a haunch part can significantly improve seismic behavior of whole system. In the current study behavior of column-tree connections with haunched beams and end plate splices have been investigated. Special attention was paid for evalu...