Performance of Grouted Splice Sleeve Connector under Tensile Load

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental study of grouted sleeve lapping connector under tensile load

The performance of the grouted sleeve lapping connector that is used to connect reinforcement bars in a precast concrete structure is studied. A total of 63 specimens, varying in bar diameter and lap length, were tested under tensile load. The failure modes, ultimate tensile strength values and load-displacement curves of the specimens are discussed in the study. Two equations are proposed for ...

متن کامل

Computational and Experimental Mechanical Modelling of a Composite Grouted Splice Sleeve Connector System

Owing to its controllable tolerance, simple operation and no need for welding at construction site, the composite system involving grouted cement material, steel material and ductile iron material is widely used as grouted splice sleeve (GSS) connector for connecting precast concrete structures. However, the current design recommendations for such a composite connection system do not accurately...

متن کامل

Shear Performance of Horizontal Joints in Short Precast Concrete Columns with Sleeve Grouted Connections under Cyclic Loading

In this study, two short precast concrete columns and two cast-in-situ concrete columns were tested under cyclic loads. It was shown that the sleeve grouted connection was equivalent to the cast-in-situ connections for short columns when the axial compression ratio was 0.6. In order to determine the influence of the axial compression ratio and the shear-span ratio on the shear capacity of the h...

متن کامل

Effect of sleeve length on deformation properties of grouted splices

Tests on 12 grouted splices were performed to investigate their deformation properties under tensile loading. Test variables included diameter and type of spliced bars and the size of splicing sleeves. Finite element method based models of the splices were built, verified and used to investigate the effect of sleeve length on the deformation properties of the grouted splices. The sleeve length ...

متن کامل

Structure and energy of a DNA dodecamer under tensile load

In the last decade, methods to study single DNA molecules under tensile load have been developed. These experiments measure the force required to stretch and melt the double helix and provide insights into the structural stability of DNA. However, it is not easy to directly relate the shape of the force curve to the structural changes that occur in the double helix under tensile load. Here, sta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES

سال: 2014

ISSN: 2289-4659,2231-8380

DOI: 10.15282/jmes.7.2014.8.0106