Performance of severely damaged reinforced concrete flat slab-column connections strengthened with Carbon Fiber Reinforced Polymer
نویسندگان
چکیده
منابع مشابه
Full Scale Reinforced Concrete Beam-Column Joints Strengthened with Steel Reinforced Polymer Systems
This paper presents the results of an experimental campaign performed at the Laboratory of Materials and Structural Testing of the University of Salerno (Italy) in order to investigate the seismic performance of reinforced concrete (RC) beam-column joints strengthened with steel reinforced polymer (SRP) systems. With the aim to represent typical façade frames’ beam-column subassemblies found in...
متن کاملStrengthening of Corrosion-Damaged Reinforced Concrete Beams with Glass Fiber Reinforced Polymer Laminates
Problem statement: This study showed the results of an experimental investigation on the strengthening of corrosion damaged reinforced concrete beams with unidirectional cloth glass fiber reinforced polymer (UDCGFRP) laminates. Approach: All the beam specimens 150×250×3000 mm were cast and tested for the present investigation. One beam specimen was neither corroded nor strengthened to serve as ...
متن کاملBehavior of Coupling Beams Strengthened with Carbon Fiber Reinforced Polymer Sheets
In this research, using the results of 6 tests, the effect of Carbon Fiber Reinforced Polymer (CFRP) sheets on the behavior of reinforced concrete coupling beams of shear walls is studied. First, in the experimental part of the study, four coupling beams with different reinforcements were manufactured and tested. Then, after the failure of the specimens, two of them were rehabilitated and stren...
متن کاملFinite Element Modeling of GFRP-Reinforced Concrete Interior Slab-Column Connections Subjected to Moment Transfer
A finite element model (FEM) was constructed using specialized three-dimensional (3D) software to investigate the punching shear behavior of interior slab-column connections subjected to a moment-to-shear ratio of 0.15 m. The FEM was then verified against the experimental results of full-scale interior slab-column connections reinforced with glass fiber reinforcement polymer (GFRP) bars previou...
متن کاملFlexural Cracks in Fiber-Reinforced Concrete Beams with Fiber-Reinforced Polymer Reinforcing Bars
Fiber-reinforced polymer (FRP) reinforcing bars have aTtracted considerable 0llellli0l1 for applications where corrosion of steel reinforcement is problemaric. Due 10 rhe generally low elastic modulus and poor bond clwracreristics of FRP as coil/pared 10 steel reinforcing bars, the use of FRP results in IGI:i?er crack widlhs under senJice loads. Fiber-reinforced concrete (FRe) is proposed for u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Composite Structures
سال: 2021
ISSN: 0263-8223
DOI: 10.1016/j.compstruct.2020.112963