Performing reactive power compensation of three-phase induction motor by using parallel active power filter

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Three-Phase Active Power Filter for Harmonic and Reactive; Power Compensation

In this paper, a 3-phase active power filter (APF) is presented to eliminate harmonics and to compensate the reactive power of an uncontrolled rectifier with capacitive loading taken as non-linear load. An APF is realized using 3-phase voltage source inverter (VSI) with dc bus capacitor. Reference source currents are estimated using P-I control over dc bus voltage and 3-phase source voltages. C...

متن کامل

Parallel Hybrid Active Power Filter for Static Reactive Power and Harmonics Compensation with Sogi-pll

In this paper, according to the lack of relevant studies based on reactive power compensation, the control method related to this subject has been investigated and applied to the Parallel Hybrid Active Power Filter (P-HAPF). Firstly, the dq base control algorithm is applied for harmonic compensation. Then, the reactive power compensation control which is supplied by active filter of hybrid acti...

متن کامل

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

Power quality issues are becoming a major concern of today's power system engineers. Shunt active power filter (SAPF) is one of the effective means for harmonic current compensation in electrical power system. The performance and dynamic characteristics of a three-phase SAPF with a simple control algorithm is presented and analyzed in this paper. This algorithm operates at fixed switching frequ...

متن کامل

Power System Harmonic Compensation Using Shunt Active Power Filter

This paper shows the method of improving the power quality using shunt active power filter. The proposedtopic comprises of PI controller, filter hysteresis current control loop, dc link capacitor. The switching signal generation for filter is fromhysteresis current controller techniques. With the all these element shunt active power filter reduce the total harmonic distortion. Thispaper represe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Advanced Researches and Engineering Journal

سال: 2020

ISSN: 2618-575X

DOI: 10.35860/iarej.731187