Perfusion Deficits Detected by Arterial Spin-Labeling in Patients with TIA with Negative Diffusion and Vascular Imaging
نویسندگان
چکیده
منابع مشابه
Perfusion deficits detected by arterial spin-labeling in patients with TIA with negative diffusion and vascular imaging.
BACKGROUND AND PURPOSE A substantial portion of clinically diagnosed TIA cases is imaging-negative. The purpose of the current study is to determine if arterial spin-labeling is helpful in detecting perfusion abnormalities in patients presenting clinically with TIA. MATERIALS AND METHODS Pseudocontinuous arterial spin-labeling with 3D background-suppressed gradient and spin-echo was acquired ...
متن کاملAssessment of Retinal and Choroidal Vascular Reactivity in Humans with Arterial Spin Labeling Perfusion Imaging
N. Maleki, D. C. Alsop, W. Dai, C. Hudson, D. Mikulis, J. Han, and J. A. Fisher Department of Medical Imaging, University of Toronto, Toronto, ON, Canada, Department of Radiology, Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, MA, United States, School of Optometry, University of Toronto, Waterloo, ON, Canada, Department of Ophthalmology & Vision Science, University of...
متن کاملMyocardial arterial spin labeling perfusion imaging with improved sensitivity
BACKGROUND Myocardial arterial spin labeling (ASL) is a noninvasive MRI based technique that is capable of measuring myocardial blood flow (MBF) in humans. It suffers from poor sensitivity to MBF due to high physiological noise (PN). This study aims to determine if the sensitivity of myocardial ASL to MBF can be improved by reducing image acquisition time, via parallel imaging. METHODS Myocar...
متن کاملPerfusion imaging using arterial spin labeling.
Arterial spin labeling is a magnetic resonance method for the measurement of cerebral blood flow. In its simplest form, the perfusion contrast in the images gathered by this technique comes from the subtraction of two successively acquired images: one with, and one without, proximal labeling of arterial water spins after a small delay time. Over the last decade, the method has moved from the ex...
متن کاملBreast Perfusion Imaging Using Arterial Spin Labeling
Delay 2 s Fig. 1. ASL experiment from a volunteer at 1.5T. (a) The imaging slice and labeling slab are depicted by yellow and blue boxes. (b) Fat-saturated SPGR image. Perfusion images are shown in (c-e) for delay times of 1 s, 1.5 s and 2 s. Arteries located close to the skin are depicted well; however, perfusion in glandular tissue is hardly visible. The yellow arrow shows an artery which doe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: American Journal of Neuroradiology
سال: 2013
ISSN: 0195-6108,1936-959X
DOI: 10.3174/ajnr.a3551