Permanent transvenous catheter pacing
نویسندگان
چکیده
منابع مشابه
Two-dimensional echocardiograms of a transvenous left ventricular pacing catheter.
A permanent transvenous pacemaker lead was placed across the atrial septum and retained in the left ventricle for eight years. M-mode echocardiograms showed a linear echocardiographic density in the left atrium and mitral valve. Cross-sectional echocardiograms further defined the location and course of the pacing lead.
متن کاملTemporary transvenous catheter-electrode pacing of the heart.
Experience with 110 separate periods of transvenous cardiac pacing by means of a catheter-electrode in 91 patients has been reviewed. Indications for the use of the catheter-electrode included (1) complete heart block with and without Adams-Stokes syndrome, (2) other arrhythmias with and without cardiogenic syncope, (3) malfunction of previously implanted permanent pacemaker units, and (4) need...
متن کاملLarge right atrial thrombosis. Rare complication during permanent transvenous endocardial pacing.
Right atrial thrombosis is a rare complication of permanent endocardial pacing. We report two cases with large right atrial thrombi which occurred during permanent endocardial electrical stimulation. Both patients were women, aged 83 and 89 years, who died suddenly, respectively, one month and 24 days after pacemaker implantation. At the time of death the two patients were in severe persistent ...
متن کاملEffects of acetylsalicylic acid on coagulation tests and haptoglobin concentrations in rabbits with permanent transvenous pacing
The aim of this study was to evaluate changes in coagulation tests, haptoglobin concentrations and leukocyte counts in rabbits with right-ventricle pacing medicated with acetylsalicylic acid (ASA). Blood was collected from 35 non-anaesthetised males from the jugular vein at baseline, one and two months after pacemaker implantation. Animals were divided into two groups: non-medicated and medicat...
متن کاملExtraction of transvenous pacing and ICD leads.
The emergence of pacing and implantable cardioverter-defibrillator (ICD) systems, along with expanding indications of these devices (e.g., cardiac resynchronization therapy and sudden cardiac death prevention), increasing infection rates, and device recalls have created the need for removing and upgrading these systems due to various reasons. Removing the pulse generator of a system is generall...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Thoracic and Cardiovascular Surgery
سال: 1973
ISSN: 0022-5223
DOI: 10.1016/s0022-5223(19)40568-0