Personal distributed exposimeter for radio frequency exposure assessment in real environments

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Personal Distributed Exposimeter for Radio Frequency Electromagnetic Field Assessment

A personal distributed exposimeter (PDE) consisting of 3 radio frequency (RF) acquisition nodes is constructed using textile antennas and wearable electronics. Numerical simulations are used to design the PDE. Calibration measurements at 950 MHz, using a human subject, are performed in an anechoic chamber. Compared to conventional exposimeters, which only measure in 1 position on the body, an e...

متن کامل

Real Time Radio Frequency Exposure for Bio-Physical Data Acquisition

Focus of this chapter is the description of the exposure systems used for data acquisition during the exposure to radiofrequency (RF) electromagnetic (EM) fields in bioelectromagnetic investigations. Such a kind of system will be referred to as real-time and can be defined as an EM structure (waveguide or antenna) able to generate and control a known and reproducible EM field and suitable to be...

متن کامل

On-body calibration and measurements using a personal, distributed exposimeter for wireless fidelity.

This paper describes the design, calibration, and measurements with a personal, distributed exposimeter (PDE) for the on-body detection of radio frequency (RF) electromagnetic fields due to Wireless Fidelity (WiFi) networks. Numerical simulations show that using a combination of two RF nodes placed on the front and back of the body reduces the 50% prediction interval (PI50) on the incident free...

متن کامل

A Personal, Distributed Exposimeter: Procedure for Design, Calibration, Validation, and Application

This paper describes, for the first time, the procedure for the full design, calibration, uncertainty analysis, and practical application of a personal, distributed exposimeter (PDE) for the detection of personal exposure in the Global System for Mobile Communications (GSM) downlink (DL) band around 900 MHz (GSM 900 DL). The PDE is a sensor that consists of several body-worn antennas. The on-bo...

متن کامل

Assessment of cellular telephone and other radio frequency exposure for epidemiologic research.

Epidemiologists are now embarking on the evaluation of the hypothesis that exposure to radio frequency energy from low-power wireless communication devices, such as portable cellular telephones, causes brain cancer and other adverse health outcomes. Even in the laboratory, exposures from radio frequency sources are difficult to quantify; their measurement in large populations for epidemiologic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Bioelectromagnetics

سال: 2013

ISSN: 0197-8462

DOI: 10.1002/bem.21793