Personal Views: Insulin infusion pump
نویسندگان
چکیده
منابع مشابه
Siphon effects on continuous subcutaneous insulin infusion pump delivery performance.
BACKGROUND The objective was to quantify hydrostatic effects on continuous subcutaneous insulin infusion (CSII) pumps during basal and bolus insulin delivery. METHODS We tested CSII pumps from Medtronic Diabetes (MiniMed 512 and 515), Smiths Medical (Deltec Cozmo 1700), and Insulet (OmniPod) using insulin aspart (Novolog, Novo Nordisk). Pumps were filled and primed per manufacturer's instruct...
متن کاملA review of the security of insulin pump infusion systems.
Insulin therapy has enabled patients with diabetes to maintain blood glucose control to lead healthier lives. Today, rather than injecting insulin manually using syringes, a patient can use a device such as an insulin pump to deliver insulin programmatically. This allows for more granular insulin delivery while attaining blood glucose control. Insulin pump system features have increasingly bene...
متن کاملA hazard analysis for a generic insulin infusion pump.
BACKGROUND Researchers at the Food and Drug Administration (FDA)/Center for Device and Radiological Health/Office of Science and Engineering Laboratories have been exploring the concept of model-based engineering as a means for improving the quality of medical device software. Insulin pumps were chosen as a research subject because their design provides the desired degree of research complexity...
متن کاملGuidelines for application of continuous subcutaneous insulin infusion (insulin pump) therapy in the perioperative period.
Case reports indicate that diabetes patients receiving outpatient insulin pump therapy have been allowed to continue treatment during surgical procedures. Although allowed during surgery, there is actually little information in the medical literature on how to manage patients receiving insulin pump therapy during a planned surgical procedure. A multidisciplinary work group reviewed current info...
متن کاملSimulating Insulin Infusion Pump Risks by In-Silico Modeling of the Insulin-Glucose Regulatory System
We present a case study on the use of robustness-guided and statistical model checking approaches for simulating risks due to insulin infusion pump usage by diabetic patients. Insulin infusion pumps allow for a continuous delivery of insulin with varying rates and delivery profiles to help patients self-regulate their blood glucose levels. However, the use of infusion pumps and continuous gluco...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BMJ
سال: 1985
ISSN: 0959-8138,1468-5833
DOI: 10.1136/bmj.291.6511.1808-a