Phase errors in diffraction-limited imaging: contrast limits for sparse aperture masking
نویسندگان
چکیده
منابع مشابه
High frame rate imaging system for limited diffraction array beam imaging with square-wave aperture weightings.
A general-purpose high frame rate (HFR) medical imaging system has been developed. This system has 128 independent linear transmitters, each of which is capable of producing an arbitrary broadband (about 0.05-10 MHz) waveform of up to +/- 144 V peak voltage on a 75-ohm resistive load using a 12-bit/40-MHz digital-to-analog converter. The system also has 128 independent, broadband (about 0.25-10...
متن کاملSparse Aperture Radar Imaging
Radar data collected from airplanes in real time is generally sparse except in very special cases. We demonstrate several tools and approaches to form images in some examples.
متن کاملSearching for Young Planets with Sparse Aperture Masking
We describe an ongoing survey to directly detect substellar and planetary companions to nearby young stars. This survey uses adaptive optics and nonredundant aperture-masking interferometry to achieve typical contrast limits of ∆K ∼6 at the diffraction limit, probing a completely new regime of parameter space. These observations have revealed many new stellar companions, but only a few companio...
متن کاملCurvelet sparse regularization for differential phase-contrast X-ray imaging
Differential phase contrast imaging (DPCI) enables the visualization of soft tissue contrast using X-rays. In this work we introduce a reconstruction framework based on curvelet expansion and sparse regularization for DPCI. We will show that curvelets provide a suitable data representation for DPCI reconstruction that allows preservation of edges as well as an exact analytic representation of t...
متن کاملDiffraction-limited imaging at IR wavelengths using aperture masks and fully-filled apertures
The performance of a phase recovery algorithm developed for speckle data collected using a pupil-plane mask has been investigated for use at near infrared wavelengths. The method, based on the radio-astronomical self-calibration technique, has been tested alongside a state-of-the-art implementation of the Knox-Thompson scheme using both simulated and real specklegrams. Our results indicate that...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Monthly Notices of the Royal Astronomical Society
سال: 2013
ISSN: 1365-2966,0035-8711
DOI: 10.1093/mnras/stt859