Photostress recovery in chronic open angle glaucoma.
Photostress recovery time was measured in 30 eyes from 15 patients with chronic open angle glaucoma, and 30 eyes from 15 individuals of a similar age group with no ophthalmological disorder. The average recovery time in patients with glaucoma was 70.47 (SD 35.39) seconds. The average recovery time in the control population was 41.97 (SD 17.34) seconds. This difference was statistically signific...
متن کاملPrevalence and correlates of leisure-time physical activity among Nigerians
BACKGROUND Physical inactivity levels are rising in many countries with major implications for the prevalence of non-communicable diseases and the general health of the population worldwide. We conducted this study to examine leisure-time physical activity levels among African adults in an urban setting. METHODS We conducted a cross-sectional study among a random sample of 1,058 adults at a g...
متن کاملEffect of age related macular degeneration on the Eger macular stressometer photostress recovery time.
AIM To assess the repeatability of Eger macular stressometer (EMS) measures of photostress recovery and determine their association with other measures of visual function. METHODS EMS photostress recovery time was measured in 90 patients with bilateral exudative age related macular degeneration (AMD), 19 with bilateral atrophic AMD and 47 with both forms of the condition (mean age 79 (SD 13) ...
متن کاملImprovement of photostress recovery testing after extracranial-intracranial bypass surgery.
A patient with carotid occlusive disease experienced episodes of light-induced amaurosis in an eye with changes of venous stasis retinopathy. Though his macula appeared normal on examination, the macular photostress test (MPST) was prolonged. After anastomosis of a superficial temporal artery with the middle cerebral artery his symptoms resolved and his MPST returned to normal. The MPST may ser...
متن کاملExtrafoveal photostress recovery testing with a scanning laser ophthalmoscope.
We used a modified photostress recovery test (PSRT) with microperimetry in a scanning laser ophthalmoscope (SLO) to evaluate the extrafoveal region. After the red-target threshold was determined, the retina was bleached with argon green laser illumination. Test spots were presented every 3 seconds at the testing point and subjects indicated when they saw the spot. We determined the recovery tim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Nigerian Optometric Association
سال: 2010
ISSN: 0795-0039,0795-0039
DOI: 10.4314/jnoa.v16i1.56627