Pitfalls during biomechanical testing — Evaluation of different fixation methods for measuring tendons endurance properties
نویسندگان
چکیده
منابع مشابه
Biomechanical Evaluation of Two Methods of Humeral Shaft Fixation
This study compared the biomechanical performance of 4.5-mm limited-contact dynamic compression plates and 3.5-mm locking compression plates for the fixation of unstable humeral shaft fractures. Composite humeri were divided into two groups: 3.5mm LC and 4.5-mm LCDC plates. Osteotomy gaps of 5-mm, simulating diaphyseal comminution, were created. Stiffness tests were performed in anterior-poster...
متن کاملdevelopment of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles
a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...
Artificial Tendons: Biomechanical Design Properties for Prosthetic Lower Limbs
1 Dept. of Veterans Affairs 2 Dept. of Rehabilitation Medicine 3 Dept. of Electrical Engineering 1660 S. Columbian Way MS 151 University of Washington University of Washington Seattle, WA 98108 USA Seattle, WA 98195 Seattle, WA 98195 [email protected] [email protected] [email protected] Abstract This paper reports on the design of an artificial tendon intended for u...
متن کاملEffects of various decellularization methods on histological and biomechanical properties of rabbit tendons
The aim of the present study was to investigate the effects of various decellularization methods on the histological and biomechanical properties of rabbit tendons. In total, six chemical reagents, including 1% t-octyl-phenoxypolyethoxyethanol (Triton-X 100), 0.5% sodium dodecyl sulfate (SDS), 1% tri-n-butyl phosphate (TnBP), 1% Triton-X 100 + 0.5% SDS, 1% TnBP + 0.5% SDS and 1% TnBP + 1% Trito...
متن کاملBiomechanical Study of Two Peripheral Suture Methods on Repaired Tendons
Flexor digitorum tendon injuries are challenging conditions to manage to ensure optimal patient outcomes. While several surgical approaches with high success rates have been developed, there remains no gold standard for suture technique for the repair of flexor tendon injuries. In this study, we compared two distinct peripheral suture methods on the strength of repaired tendons. Pig flexor digi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Physiologica Hungarica
سال: 2016
ISSN: 0231-424X,1588-2683
DOI: 10.1556/036.103.2016.1.8