PO-0833: Voxel-based dose-painting with a commercial treatment planning system by using two different planning methods
نویسندگان
چکیده
منابع مشابه
Dose calculation accuracy of lung planning with a commercial IMRT treatment planning system
The dose calculation accuracy of a commercial pencil beam IMRT planning system is evaluated by comparison with Monte Carlo calculations and measurements in an anthropomorphic phantom. The target volume is in the right lung and mediastinum and thus significant tissue inhomogeneities are present. The Monte Carlo code is an adaptation of the MCNP code and the measurements were made with TLD and fi...
متن کاملA study of planning dose constraints for treatment of nasopharyngeal carcinoma using a commercial inverse treatment planning system.
PURPOSE The purpose of this study was to develop and test planning dose constraint templates for tumor and normal structures in the treatment of nasopharyngeal carcinoma (NPC) using a specific commercial inverse treatment planning system. METHODS AND MATERIALS Planning dose constraint templates were developed based on the analyses of dose-volume histograms (DVHs) of tumor targets and adjacent...
متن کاملAssessment of two different dose distribution algorithms (Clarkson and Superposition) in PCRT3D treatment planning system for Esophagus Cancer by using 3DCRT technique
Introduction: The functionality and quality of any treatment planning system (TPS) strongly depends on the type of Algorithm which is used by it. Obviously, the role of dose distribution algorithms in calculation of prescribed dose inside the tumor in modern radiotherapy techniques has more important than past to achieve the best clinical outcomes, especially in tumors which ar...
متن کاملVerification of tangential breast treatment dose calculations in a commercial 3D treatment planning system
The accuracy of the photon convolution/superposition dose algorithm employed in a commercial radiation treatment planning system was evaluated for conditions simulating tangential breast treatment. A breast phantom was fabricated from machineable wax and placed on the chest wall of an anthropomorphic phantom. Radiographic film was used to measure the dose distribution at the axial midplane of t...
متن کاملValidation of treatment planning system using simulation PRIMO code.
Introduction: In radiation therapy, in order to double-check the dosimetric results of the main treatment planning system (TPS), a distinct TPS, with few capacitances in terms of contouring and a variety of dose calculation algorithms is used. This system has the capability to double check the planification and the accurate prediction of dose distribution in order to be ensured...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2013
ISSN: 0167-8140