Porous CARDIOFORM Septal Occluder Balloons Within the Right Atrial Cavity

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter atrial septal defect closure in an infant (body weight 6.4 kg) using the GORE CARDIOFORM septal occluder (GCSO)

INTRODUCTION Transcatheter closure has become the treatment of choice for secundum atrial septal defects (ASD II), but particularly in small children, there is concern regarding procedure-related complications. CASE DESCRIPTION We report on a 10-month-old infant, body weight of 6.4 kg, with a large ASD who was referred for failure to thrive and dyspnea on exertion. Echocardiography showed two...

متن کامل

Right atrial ball thrombus associated with atrial septal occluder device: A late complication of transcatheter atrial septal defect closure

In a large autopsy study, intracardiac ball thrombi are usually seen in the left atrium and rarely seen in the right atrium. They may be one or more in number. Right atrial ball thrombus may appear as a complication of central venous catheterization or be coexistent with tricuspid stenosis. A 42-year-old woman who began routine hemodialysis 5 years ago due to chronic kidney disease was admitted...

متن کامل

Assessment of right atrial and right ventricular size in children after percutaneous closure of secundum atrial septal defect with Amplatzer septal occluder

INTRODUCTION The aim of this study was to evaluate the right atrial (RA) and right ventricular (RV) size, and the speed of their normalization, in children after percutaneous closure of secundum atrial septal defect with the Amplatzer septal occluder. MATERIAL AND METHODS The study group consisted of 42 children, aged 4.5 to 18.5 years. The following measurements (indexed to body surface area...

متن کامل

Transcatheter closure of atrial septal defects in adults with the Amplatzer septal occluder.

OBJECTIVE To assess the efficacy and complications of device occlusion of atrial septal defects in adults, using the Amplatzer septal occluder (ASO). DESIGN A prospective interventional study. SETTING Paediatric cardiology departments in two European teaching hospitals. PATIENTS The first 20 patients accepted for atrial septal defect device occlusion, on the basis of transoesophageal echo...

متن کامل

Animal experimental implantation of an atrial septal defect occluder system.

OBJECTIVE To establish the implantation technique for the atrial septal defect occluder system (ASDOS) device in an experimental animal model and to determine long term mechanical stability of the device and its in vivo properties in terms of biocompatibility and tissue reaction. MATERIALS AND METHODS An atrial septal defect was created and the device implanted in 17 pigs (mean weight 30 kg)....

متن کامل