Potentiometric Determination of Moxifloxacin by Solid-Contact ISEs in Wastewater Effluents
نویسندگان
چکیده
In recent years, the use of ion-selective membranes in sensing and assessment environmental contaminants has become a critical goal. Using sodium tetraphenylborate (TPB) phosphotungstic acid (PTA) as ion-pairing agents, two sensitive selective sensors were manufactured to evaluate electrochemical response moxifloxacin hydrochloride (MOX). The optimal behavior was attained by fine-tuning all assay parameters. membranes’ performance pH range from 1.0 5.0 with linearity between 1 × 10−6 M 10−2 M. MOX–TPB MOX–PTA membrane electrodes have Nernstian slopes 59.2 ± 0.60 mV/decade 58.4 0.50 mV/decade, respectively. proposed method used determine MOX its pure form well real pharmaceutical wastewater effluents. fabricated effectively applied for determination actual effluents without need any pre-treatment processes.
منابع مشابه
Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode
Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode Tanji Yin1 2 3 ∗ and Wei Qin1 1Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research YIC , Chinese Academy of Sciences CAS ; Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China 2So...
متن کاملNovel Solid-Contact Ion-Selective Microelectrodes for Localized Potentiometric Measurements
The design and properties of novel type of solid-contact ionophore-based ion-selective microelectrodes are reported. The microelectrode is based on an insulated needle-shaped metallic wire with an exposed apex. The ion-to-electron transducer is made of poly(3-octylthiophene-2,5-diyl) and placed between an ion-selective membrane and the metallic tip. The ion-selective polyvinyl chloride-based me...
متن کاملPotentiometric Determination of Cyanide in Effluents Having High Concentration of Chloride
The est~mat~on f cyanide IS generally done by titrimetry, colorimetry and polarography but each method has its own limitations. Argenlometric titration method IS not satisfactory at low cyanide concentralion at ppm levels. Distillation and colorimetry method is accurate but time consuming. Presence of large quant~t~es of chloride does not permit the use of ion selective electrodes. Other method...
متن کاملPotentiometric determination of moxifloxacin in some pharmaceutical formulation using PVC membrane sensors
BACKGROUND The construction and electrochemical response characteristics of Poly (vinyl chloride) membrane sensors for moxifloxacin HCl (MOX) are described. The sensing membranes incorporate ion association complexes of moxifloxacin cation and sodium tetraphenyl borate (NaTPB) (sensor 1), phosphomolybdic acid (PMA) (sensor 2) or phosphotungstic acid (PTA) (sensor 3) as electroactive materials. ...
متن کاملGreen Potentiometric Method for Determination of Triprolidine Hydrochloride and Pseudoephedrine Hydrochloride in their Different Pharmaceutical Matrices using Liquid and Solid Contact Gold Electrodes
Factors affecting the performance of polyvinyl chloride based ion selective electrode such as using different cationic exchangers and ionophores as well as sensor fabrication procedures were recently the scope of study by several researchers. This work presents an environment friendly electro-analytical method for the determination of Triprolidine HCl (TRI) and Pseudoephedrine HCl (PSE). A comp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Chemosensors
سال: 2022
ISSN: ['2227-9040']
DOI: https://doi.org/10.3390/chemosensors10040146