Potentiometric enantioselective membrane electrode for s-enalapril assay
نویسندگان
چکیده
منابع مشابه
Potentiometric enantioselective membrane electrode for s-enalapril assay
A novel potentiometric, enantioselective membrane electrode based on graphite paste (graphite powder and paraffin oil), impregnated with 10–3 mol/L 2-hydroxy-3-trimethylammoniopropyl-β-cyclodextrin (as chloride salt) solution, has been constructed. The potentiometric, enantioselective membrane electrode can be used for the reliable assay of S-enalapril as raw material and from its pharmaceutica...
متن کاملPolymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions
Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...
متن کاملReactive intermediates-induced potential responses of a polymeric membrane electrode for ultrasensitive potentiometric biosensing.
Reactive intermediates rather than stable reactants or products have been found to induce large potential responses on an appropriately formulated polymeric membrane electrode, which provides a novel methodology for ultrasensitive potentiometric biosensing based on the horseradish peroxidase-H(2)O(2) oxidation reaction.
متن کاملPotentiometric Based Membrane Sensor for Zinc Ion
A PVC-based membrane of 12-crown-4 exhibits good response for Zn2+ in a wide concentration range (7.08 10-5-1.00 10-1 M) with a non-nernstian slope of 20.5 mv per decade of concentration of Zn2+. The response time of sensor is <10 s and the membrane can be used for more than 3 months without observing any divergence. In addition, the proposed sensor exhibits very good selectivity for Zn2+ o...
متن کاملPotentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode
Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode Tanji Yin1 2 3 ∗ and Wei Qin1 1Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research YIC , Chinese Academy of Sciences CAS ; Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China 2So...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analusis
سال: 1999
ISSN: 0365-4877,1286-482X
DOI: 10.1051/analusis:1999105