POTENTIOMETRIC RESPONSE OF A GRAPHITE ELECTRODE MODIFIED WITH COBALT PHTHALOCYANINE FOR THIOLS AND DISULFIDES

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

COBALT PHTHALOCYANINE MODIFIED CARBON PASTE ELECTRODE AS A POTENTIOMETRIC SENSOR FOR DETERMINATION OF ASCORBIC ACID

A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...

متن کامل

cobalt phthalocyanine modified carbon paste electrode as a potentiometric sensor for determination of ascorbic acid

a carbon paste electrode modified with cobalt (ii) phthalocyanine (copc) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. the potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 m (?1- 1800 µg ml ) with a nernstian slope of 56 mv at ph 7. the limit of detection was 0.2 µg ml ascor...

متن کامل

Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine

A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...

متن کامل

flow-injection amperometric determination of ascorbic acid using a graphite-epoxy composite electrode modified with cobalt phthalocyanine

a flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(ii) phthalocyanine (copc) modified graphite-epoxy electrode. the amperometric respons was evaluated with regard to ph, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. the limit of detection...

متن کامل

Flow-injection electrochemical determination of citric acid using a cobalt(II)-phthalocyanine modified carbon paste electrode.

The electrocatalytic activity of cobalt(II)-phthalocyanine immobilized in a carbon paste electrode for citric acid oxidation under a diffusion-controlled electrochemical process was employed to develop a selective flow injection amperomettric analysis method. Under optimized conditions, rapid and reliable determinations of citric acid (65 samples per hour) were achieved for analyses of commerci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Boletín de la Sociedad Chilena de Química

سال: 2000

ISSN: 0366-1644

DOI: 10.4067/s0366-16442000000200010