Potentiometric Sensor For Analgin Determination In Pharmaceutical Formulations
نویسندگان
چکیده
منابع مشابه
Potentiometric Determination of Captopril in Pharmaceutical Formulations
Captopril, chemically know as 1-[(2S)-3mercapto-2-methylpropionyl]-L-proline, (CPT) is used therapeutically as an antihypertensive agent [11, 15], which is also prescribed for the treatment of congestive hart failure [6]. Several types of analytical procedures have been proposed for the analysis of captopril in pharmaceuticals formulations. These procedures include capillary electrophoresis [13...
متن کاملPotentiometric determination of fentanyl in pharmaceutical formulations.
A poly (vinyl chloride) membrane electrode with dibutyl phthalate as plasticizer based on the fentanyl-phosphotungstate ion-association complex as ion-exchange site for the determination of fentanyl citrate in injections was developed. A linear response for 1 x 10(-5)-1 x 10(-2) mol dm(-3) drug with a slope of 55.9 +/- 0.4 mV per decade was established. The optimum pH range was 1-7. The lower d...
متن کاملPotentiometric Determination of Quetiapine Fumarate in Pharmaceutical Formulations
Quetiapine (QTF) is a potent serotonin and dopamine receptor antagonist used to treat major depressive disorders and schizophrenia. A simple, precise, accurate and costeffective titrimetric method for the determination of QTF in bulk drug and in its dosage forms has been developed and validated. The method is based on the potentiometric titration of QTF in glacial acetic acid with acetous perch...
متن کاملPerformance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations
A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...
متن کاملPerformance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations
A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Methods and Objects of Chemical Analysis
سال: 2020
ISSN: 2413-6166,1991-0290
DOI: 10.17721/moca.2020.66-72