Potentiometric sensor for Betahistine determination in pharmaceuticals, urine and blood serum

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potentiometric Sensor for Furosemide Determination in Pharmaceuticals, Urine, Blood Serum and Bovine Milk

A construção, avaliação e aplicação analítica de um sensor potenciométrico do tipo PtHgHg 2 (Fur) 2 Grafite, onde Fur significa íon 4-cloro-N-furfuril-5-sulfamoil-antranilato, são descritas. O eletrodo responde a Fur com sensibilidade de (−58,4 ± 0,9) mV década no intervalo de 5,0 × 10-1,0 × 10 mol L, a pH 7,0-9,0 e com um limite de detecção de 3,8 × 10 mol L. O eletrodo é facilmente constru...

متن کامل

A New Potentiometric Sensor for Determination and Screening Phenylalanine in Blood Serum Based on Molecularly Imprinted Polymer

Methods routinely utilized for detection of phenylalanine in new-born blood consist of enzymatic assays, lacking sensitivity and HPLC assays which are expensive and time-consuming to conduct. We, here, report for the first time, the construction of a phenylalanine sensitive electrode, on the basis of a selective molecularly imprinted polymer, offering sensitivity, economy and ease of use for th...

متن کامل

Ofloxacin determination in urine, serum and pharmaceuticals using an automatic flow potentiometric system.

An automatic system was developed to determine ofloxacin in biological fluids and pharmaceutical formulations. Drug detection was carried out by a potentiometric membrane sensor based on [bis(trifluoromethyl)phenyl]borate as molecular-recognition material. The tubular shaped detector system was solidly attached to the manifold, creating a high-throughput stable setup (50 samples per hour) appro...

متن کامل

A New Potentiometric Sensor for Determination and Screening Phenylalanine in Blood Serum Based on Molecularly Imprinted Polymer

Methods routinely utilized for detection of phenylalanine in new-born blood consist of enzymatic assays, lacking sensitivity and HPLC assays which are expensive and time-consuming to conduct. We, here, report for the first time, the construction of a phenylalanine sensitive electrode, on the basis of a selective molecularly imprinted polymer, offering sensitivity, economy and ease of use for th...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Brazilian Chemical Society

سال: 2010

ISSN: 0103-5053

DOI: 10.1590/s0103-50532010001200011