Potentiometric VOCs detection using 8YSZ based oxygen sensor
نویسندگان
چکیده
منابع مشابه
Potentiometric Based Membrane Sensor for Zinc Ion
A PVC-based membrane of 12-crown-4 exhibits good response for Zn2+ in a wide concentration range (7.08 10-5-1.00 10-1 M) with a non-nernstian slope of 20.5 mv per decade of concentration of Zn2+. The response time of sensor is <10 s and the membrane can be used for more than 3 months without observing any divergence. In addition, the proposed sensor exhibits very good selectivity for Zn2+ o...
متن کاملPreoxidation for colorimetric sensor array detection of VOCs.
A disposable preoxidation technique that dramatically improves the detection and identification of volatile organic compounds (VOCs) by a colorimetric sensor array is reported. Passing a vapor stream through a tube packed with chromic acid on silica immediately before the colorimetric sensor array substantially increases the sensitivity to less-reactive VOCs and improves the limits of detection...
متن کاملDetection of volatile organic compounds (VOCs) using SnO2 gas-sensor array and artificial neural network
This paper presents design and development of an electronic nose system based on tin oxide gas-sensors array and artificial neural network (ANN) for the identification of some of the volatile organic compounds (VOCs) relevant to environmental monitoring such as propane-2-ol, methanol, acetone, ethyl methyl ketone, hexane, benzene and xylene. An array of SnO2-based thick-film gas sensors doped w...
متن کاملAn ISFET-based anion sensor for the potentiometric detection of organic acids in liquid chromatography
Ž . Ž . An ion-selective field effect transistor ISFET was applied as a potentiometric detector in liquid chromatography LC for the Ž determination of organic acids. The ISFET was prepared by coating the gate insulator of the encapsulated transistor with a poly vinyl . Ž . chloride PVC matrix membrane containing methyltridodecylammoniumchloride, which enables the detection of organic anions. Th...
متن کاملUnlabeled multi tumor marker detection system based on bioinitiated light addressable potentiometric sensor.
Multi biomarkers' assays are of great significance in clinical diagnosis. A label-free multi tumor markers' parallel detection system was proposed based on a light addressable potentiometric sensor (LAPS). Arrayed LAPS chips with basic structure of Si(3)N(4)-SiO(2)-Si were prepared on silicon wafers, and the label-free parallel detection system for this component was developed with user friendl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Ceramic Society of Japan
سال: 2008
ISSN: 1882-0743,1348-6535
DOI: 10.2109/jcersj2.116.777