Power active filter control based on a resonant disturbance observer
نویسندگان
چکیده
منابع مشابه
Power Active Filter Control Based on a Resonant Disturbance Observer
Active filters are power electronics devices used to eliminate harmonics from the distribution network. This article presents an active disturbance rejection control scheme for active filters. The controller is based on a linear disturbance observer combined with a disturbance rejection scheme. The parameter tuning is based on a combined pole placement and an optimal estimation based on Kalman-...
متن کاملa novel active power filter control methodology
this paper presents a new control methodology for active power filters that provide an adaptive online harmonic estimation with partial and selective harmonic reduction schemes, which has been implemented within an integrated controller. the proposed approach is to provide partial and selective reduction of those individual harmonics which exceed the recommended levels as set by regulatory bodi...
متن کاملPerformance Scrutiny of Two Control Schemes Based on DSM and HB in Active Power Filter
This paper presents a comparative analysis between two current control strategies, constant source power and generalized Fryze current, used in Active Power Filter (APF) applications having three different modulation methods. The Hysteresis Band (HB) and first-order Delta-Sigma Modulation (DSM) as well as the second-order DSM is applied. The power section of the active power filter is viewed as...
متن کاملVoltage Control and Load Sharing in a DC Islanded Microgrid Based on Disturbance Observer
Increasing DC loads along with DC nature of distributed energy resources (DERs) raises interest to DC microgrids. Conventional droop/non-droop power-sharing in microgrids suffers from load dependent voltage deviation, slow transient response, and requires the parameters of the loads, system and DERs connection status. In this paper, a new nonlinear decentralized back-stepping control strategy f...
متن کاملMitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IET Power Electronics
سال: 2015
ISSN: 1755-4543,1755-4543
DOI: 10.1049/iet-pel.2014.0032