Power Factor Correction Without Current Sensor Based on Digital Current Rebuilding

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reactive current control through SVC for load power factor correction

This paper discusses a new technique for controlling SVCs (Fixed Capacitor–Thyristor Controlled Reactor) in power systems with the aim of canceling the reactive current component of the load. A complete model of the SVC with its control circuit is set up and simulated in the EMTDC program. The generated harmonics from the proposed SVC controller are considered to design simple tuned filters to ...

متن کامل

Inductive Current Sensor Based on Nanocrystalline Alloys

− In this paper are described the design and application of an inductive magnetic sensor based on nanocrystalline alloys. The sensor is adjusted for measurement and monitoration of currents with intensities from some microamperes to miliamperes. Its functional behaviour, performance and a specific application are described. One of the biggest advantages of this current sensor is its non-invasiv...

متن کامل

Power Factor Correction in Digital World

There are various reasons why power factor correction circuit is used in various power supplies in large systems. The PFC (Power Factor Correction) at input stage becomes real necessary when the input power goes above 1kW typically. Recent advances in PFC include interleaving of two out-of-phase circuits to gain many system level advantages. Enough has been discussed about the advantages of int...

متن کامل

Digital Control For Power Factor Correction

This thesis focuses on the study, implementation and improvement of a digital controller for a power factor correction (PFC) converter. The development of the telecommunications industry and the Internet demands reliable, cost-effective and intelligent power. Nowadays, the telecommunication power systems have output current of up to several kiloamperes, consisting of tens of modules. The high-e...

متن کامل

Fault Location on Compensated Transmission Lines without Current Measurement

This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Power Electronics

سال: 2010

ISSN: 0885-8993,1941-0107

DOI: 10.1109/tpel.2009.2039231