The increasing application of nonlinear loads may cause distribution system power quality issues. This work presents a control of Single-phase Grid Interactive Inverters with nonlinear loads and a technique for Harmonic compensation and power factor correction of nonlinear loads employing Current Controlled Voltage Source Inverter. This work will focus on the design methodology and the analysis...

متن کامل

A New Control Method for Single-Phase Grid-Connected Inverter Using Instantaneous Power Theory

Because of installation for local consumers and since it is free of all contaminations, connecting photovoltaic cells to the grid via single-phase inverter is significantly on the rise. In this paper, a new simple current control is proposed for a single-phase grid-connected voltage source inverter. Using the PQ theory and modelling a single-phase system as an unbalanced three-phase system, a m...

متن کامل

Optimization of the Lyapunov Based Nonlinear Controller Parameters in a Single-Phase Grid-Connected Inverter

In this paper, optimization of the backstepping controller parameters in a grid-connected single-phase inverter is studied using Imperialist competitive algorithm (ICA), Genetic Algorithm (GA) and Particle swarm optimization (PSO) algorithm. The controller is developed for the system based on state-space averaged model. By selection of a suitable Lyapunov function, stability of the proposed con...

متن کامل

Fuzzy Based Improvement of Power Quality in 1-Φ Grid-Connected PWM Voltage Source Inverter

The Distributed generated system originated due to the demand of electrical energy and keen scarcity of conventional energy sources. The main problem is the harmonization of the DG to the utility grid. Usually, for synchronizing the utility grid with DG source current regulated PWM voltage-source inverters (VSI) are used in order to meet the following objectives: 1) To improve grid stability 2)...

متن کامل

Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes

A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inver...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering

سال: 2015

ISSN: 2320-3765,2278-8875

DOI: 10.15662/ijareeie.2015.0403014