Precision efficiency calibration of a high-purity co-axial germanium detector at low energies
نویسندگان
چکیده
منابع مشابه
Performance of a Low-Background High Purity Germanium Detector with a Novel EndCap
Low background HPGe detectors have been used for many years in the measurement of low activities of radionuclides in various materials. With the increased importance of nuclear forensics, low background detectors are in increasing demand. The endcap and other materials used in low background detector construction must be selected to have the lowest activity possible. In some cases, the material...
متن کاملThe Best Choice of High Purity Germanium (HPGe) Detector
below and are based on some basic concepts about how the detection process works, how gamma rays penetrate materials, and the principles of gamma-ray spectroscopy. Unresolved choice issues can be reduced to a level where they have little or no impact on the resultant performance of the spectrometry system. This document explains how you can easily make a wise, well-informed choice. We assume yo...
متن کاملHigh purity germanium detector in gamma-ray spectrometry
We measured full energy peak efficiency of High-Purity Germanium detector which is important for gamma-ray spectrometry experiments. A brief but very effective description on the basic formation of detector crystal and creation of signal pulse has been presented here. This article is furnished in such a way that the contents find useful and interesting to physics and electronics students, educa...
متن کاملHigh precision 89Y(α,α)89Y scattering at low energies
G. G. Kiss,1,* P. Mohr,2 Zs. Fülöp,1 D. Galaviz,3,† Gy. Gyürky,1 Z. Elekes,1 E. Somorjai,1 A. Kretschmer,4 K. Sonnabend,4 A. Zilges,5 and M. Avrigeanu6 1Institute of Nuclear Research (ATOMKI), H-4001 Debrecen, Hungary 2Diakonie-Klinikum, D-74523 Schwäbisch Hall, Germany 3Instituto de Estructura de la Materia, CSIC, E-28006 Madrid, Spain 4Institut für Kernphysik, Technische Universität Darmstadt...
متن کاملSpatially uniform calibration of a liquid xenon detector at low energies using (83m)Kr.
A difficult task with many particle detectors focusing on interactions below approximately 100 keV is to perform a calibration in the appropriate energy range that adequately probes all regions of the detector. Because detector response can vary greatly in various locations within the device, a spatially uniform calibration is important. We present a new method for calibration of liquid xenon (...