Precision Measurement of then−He3Incoherent Scattering Length Using Neutron Interferometry

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Precision measurement of the n-3He incoherent scattering length using neutron interferometry.

We report the first measurement of the low-energy neutron-(3)He incoherent scattering length using neutron interferometry: b_{i};{'} = (-2.512 +/- 0.012 stat +/- 0.014 syst) fm. This is in good agreement with a recent calculation using the AV18 + 3N potential. The neutron-(3)He scattering lengths are important for testing and developing nuclear potential models that include three-nucleon forces...

متن کامل

Precision neutron-interferometric measurement of the coherent neutron-scattering length in silicon

A. Ioffe,* D. L. Jacobson, M. Arif, M. Vrana, S. A. Werner, P. Fischer, G. L. Greene, and F. Mezei Berlin Neutron Scattering Center, Hahn-Meitner-Institut, Glienicker Strasse 100, 14109 Berlin, Germany St. Petersburg Nuclear Physics Institute, Gatchina, Leningrad District 188350, Russia National Institute of Standards and Technology, Gaithersburg, Maryland 20899 Nuclear Physics Institute of CAS...

متن کامل

Entanglement interferometry for precision measurement of atomic scattering properties.

We report on a matter wave interferometer realized with entangled pairs of trapped 87Rb atoms. Each pair of atoms is confined at a single site of an optical lattice potential. The interferometer is realized by first creating a coherent spin superposition of the two atoms and then tuning the interstate scattering length via a Feshbach resonance. The selective change of the interstate scattering ...

متن کامل

High-Precision Determination of the Neutron Coherent Scattering Length

The neutron coherent scattering length b c has been determined interferometrically to an uncertainty of about 5 × 10(-5) by measuring the nondispersive phase. We propose improving the uncertainty to about 10(-6) by optimizing various parameters of the interferometric experiment. Any uncertainty in the b c determination arising from possible variations in the constitution of the ambient air can ...

متن کامل

Measurement of Bunch Length Using Intensity Interferometry

Abstract Intensity interferometry is one of the most conventional methods for measuring the length of a short light pulse (from ps to sub-ps). We attempted to apply this method to the measurement of bunch length at the Photon Factory. We tested both the second-harmonic autocorrelation method and the two-photon interference method. With both methods, we observed the autocorrelation signal of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Review Letters

سال: 2009

ISSN: 0031-9007,1079-7114

DOI: 10.1103/physrevlett.102.200401