Precision Measurements in Helium at 58 nm: Ground State Lamb Shift and the11S-21PTransition Isotope Shift

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Precision measurements in helium at 58 nm: Ground state lamb shift and the 1 S-2 P transition isotope shift.

A source of narrow bandwidth (,800 MHz) tunable laser radiation at 58.4 nm has been developed and is applied to record the 11S-21P transition in He and He. From the He transition frequency of 171 134.8936s58d cm21 a fivefold improved ground state Lamb shift of 1.3763s58d cm21 is deduced, in good agreement with the theoretical value of 1.3755s10d cm21. The measured 11S-21P transition isotope shi...

متن کامل

Lamb shift measurement in the 1 1 S ground state of helium

With a phase-modulated extreme ultraviolet pulsed laser source the frequency of the 1 S-2 P transition of helium at 58 nm has been measured. The phase modulation scheme enabled measurement and reduction of frequency chirp, usually limiting pulsed precision spectroscopy. From the measured transition frequency of 5 130 495 083~45! MHz, a fourfold improved value of the ground state Lamb shift of 4...

متن کامل

Lamb Shift in Muonic Helium Ion

The Lamb shift (2P1/2 − 2S1/2) in the muonic helium ion (μ 2He) is calculated with the account of contributions of orders α3, α4, α5 and α6. Special attention is given to corrections of the electron vacuum polarization, the nuclear structure and recoil effects. The obtained numerical value of the Lamb shift 1381.716 meV can be considered as a reliable estimate for the comparison with experiment...

متن کامل

Lamb-dip stabilized 543-nm He-Ne lasers and isotope shift of Ne 3s2→ 2p10 transition

Internal-mirror 543-nm He-20Ne and He-22Ne lasers are frequency-stabilized to the Lamb-dip of their tuning curves. Frequency stability of 2×10−11 and frequency resettability of 4×10−9 (or 2 MHz) are achieved. The absolute frequencies of the two lasers are determined by frequencycomparing with an iodine-stabilized 543-nm laser. The isotope shift between 20Ne and 22Ne is measured to one order of ...

متن کامل

Hyperfine structure and isotope shift measurements

The 4d S0 ground-state transitions to the 4d 9 5p configuration of palladium (Pd) have been studied. For this purpose, a tunable, single-mode, deep-UV cw laser has been built to generate the sum frequency of a frequency-doubled Ti:S laser with a second Ti:S laser. The produced wavelengths range from 244 to 276 nm. From the measured spectra the frequency splitting due to hyperfine structure and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Review Letters

سال: 1996

ISSN: 0031-9007,1079-7114

DOI: 10.1103/physrevlett.76.1216