Predicting maximum eccentric strength from surface EMG measurements

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predicting maximum eccentric strength from surface EMG measurements.

The origin of the well-documented discrepancy between maximum voluntary and in vitro tetanic eccentric strength has yet to be fully understood. This study aimed to determine whether surface EMG measurements can be used to reproduce the in vitro tetanic force-velocity relationship from maximum voluntary contractions. Five subjects performed maximal knee extensions over a range of eccentric and c...

متن کامل

Predicting 3D lip shapes using facial surface EMG

AIM The aim of this study is to prove that facial surface electromyography (sEMG) conveys sufficient information to predict 3D lip shapes. High sEMG predictive accuracy implies we could train a neural control model for activation of biomechanical models by simultaneously recording sEMG signals and their associated motions. MATERIALS AND METHODS With a stereo camera set-up, we recorded 3D lip ...

متن کامل

Effects of strength training on muscle fatigue mapping from surface EMG and blood metabolites.

PURPOSE this study examined the effects of heavy resistance training on the relationships between power loss and surface EMG (sEMG) indices and blood metabolite concentrations on dynamic exercise-induced fatigue with the same relative load as in pretraining. METHODS twelve trained subjects performed five sets consisting of 10 repetitions in the leg press, with 2 min of rest between sets befor...

متن کامل

Noise Removal from Surface Respiratory EMG Signal

The aim of this study was to remove the two principal noises which disturb the surface electromyography signal (Diaphragm). These signals are the electrocardiogram ECG artefact and the power line interference artefact. The algorithm proposed focuses on a new Lean Mean Square (LMS) Widrow adaptive structure. These structures require a reference signal that is correlated with the noise contaminat...

متن کامل

Histological skeletal muscle damage and surface EMG relationships following eccentric contractions.

This study examined the effects of a different number of eccentric contractions (ECs) on histological characteristics, surface electromyogram (EMG) parameters (integral EMG, iEMG; muscle fiber conduction velocity, MFCV; and action potential waveform), and isometric peak torque using the rat EC model. Male Wistar rats (n = 40) were anesthetized, and ECs were initiated in the tibialis anterior mu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Biomechanics

سال: 2009

ISSN: 0021-9290

DOI: 10.1016/j.jbiomech.2009.04.037