Prediction of Burnout Heat Flux of Forced Convection
نویسندگان
چکیده
منابع مشابه
Burnout in Forced Convection
Data are presented for burnout in forced coivection nucleate boiling of water at pressures above 500 psia. A dimensionless correlation is devised for. the M.I.T. data which is found to be valid for certain recent data reported by Argonne National Laboratory.
متن کاملForced-convection boiling and critical heat flux from a linear array of discrete heat sources
Forced-convection boiling experiments were performed with FC-72, a 3M Fluorinert, at 1.36 bar on a linear array of nine discrete heat sources simulating microelectronic chips, which were flushmounted in a vertical. rectangular channel. The inlet velocity and liquid subcooling were varied from 13 to 400 cm s’ and 3 to 36”C, respectively. Special design of the experimental apparatus allowed each ...
متن کاملNanofluid forced convection through a microtube with constant heat flux and slip boundary
Given the need to increase the efficiency of heat transfer in thermal systems, especially systems using nanofluids in microscale and nanoscale heat transfer equipment ideas to improve their performance is very good.In present study, the flow and heat transfer of Water-Cu nanofluid in micro-tube with slip regime with constant wall heat flux numerically simulated with low Reynolds numbers. Sl...
متن کاملHeat Transfer Study of Perforated Fin under Forced Convection
Fins are protrusions on a heat transfer surface to augment heat transfer rate from it. The increase in area exposed to convection in case of finned surfaces results in increased heat transfer rate. In this study heat transfer characteristics of a pin fin with perforation is numerically analyzed. A pin fin is fabricated and experiments are done under forced convection conditions. The experimenta...
متن کاملChannel height effects on forced-convection boiling and critical heat flux from a linear array of discrete heat sources
Due to the lack of understanding in the literature of channel height effects on forced-convection boiling and critical heat flux (CHF) in rectangular channels, experiments were performed with FC-72 at 1.36 bar for channel heights of 2, 5, and 10 mm. Boiling heat transfer from a linear array of nine discrete heat sources simulating microelectronic chips was investigated for velocity and liquid s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Atomic Energy Society of Japan / Atomic Energy Society of Japan
سال: 1962
ISSN: 0004-7120
DOI: 10.3327/jaesj.4.224