Preliminary Results of Femtosecond Laser–Assisted Descemet Stripping Endothelial Keratoplasty
نویسندگان
چکیده
منابع مشابه
Results of Femtosecond Laser-Assisted Descemet Stripping Automated Endothelial Keratoplasty
PURPOSE To evaluate femtosecond laser in DSAEK surgery as an improvement to manual DSAEK. SETTINGS Department of Ophthalmology, Cairo University. DESIGN A retrospective observational clinical study. METHODS 20 eyes with SBK and Fuchs' dystrophy underwent a Femto-assisted DSAEK by laser cutting of two matching posterior stromal discs in the recipient and donor corneas and then fitting the ...
متن کاملFemtosecond Laser Refractive Surgery after Descemet Stripping-Automated Endothelial Keratoplasty
Purpose. To report the use of femtosecond laser-assisted in situ keratomileusis (LASIK) in the treatment of hyperopia subsequent to Descemet stripping-automated endothelial keratoplasty (DSAEK). Methods. Interventional case report. Results. A 66-year-old woman with Fuchs endothelial dystrophy developed bullous keratopathy after cataract surgery in her right eye. She underwent DSAEK with a signi...
متن کاملDescemet stripping automated endothelial keratoplasty
Endothelial keratoplasty is at present the gold standard for surgical treatment of corneal endothelial pathologies not associated with significant corneal scar. Tremendous progress has been made in recent years in improving the technology of endothelial keratoplasty techniques, such as descemet stripping automated endothelial keratoplasty (DSAEK) and descemet membrane endothelial keratoplasty. ...
متن کاملFemtosecond laser and microkeratome-assisted Descemet stripping endothelial keratoplasty: first clinical results.
AIM To perform Descemet stripping automated endothelial keratoplasty (DSAEK) using a novel technique to obtain very thin (<100 µm) posterior corneal disks. METHODS Twenty five DSAEK grafts were prepared with two sequential cuts: the first cut, of variable thickness, was made with a femtosecond laser and the second with a 300 µm microkeratome head. Spectacle corrected visual acuity, endothelia...
متن کاملDescemet-stripping Automated Endothelial Keratoplasty—A Review
Descemet-stripping automated endothelial keratoplasty (DSAEK) has become the procedure of choice to treat corneal endothelial dysfunction. The technique involves replacing the diseased host endothelium with a graft consisting of a thin layer of posterior stroma, Descemet membrane, and endothelium. In comparison to penetrating keratoplasty (PK), DSAEK confers quicker visual and structural recove...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Archives of Ophthalmology
سال: 2008
ISSN: 0003-9950
DOI: 10.1001/archopht.126.10.1351