Preoxygenation in children using expired oxygraphy
نویسندگان
چکیده
منابع مشابه
Preoxygenation in children using expired oxygraphy.
We performed preoxygenation on 25 patients, aged 1-12 yr. End-tidal oxygen sampling was used to find the duration of preoxygenation required to reach an end-tidal oxygen fraction of 0.9. All children reached this end-point within 80 s, which was markedly more rapid than that observed in adult subjects. The clinical applications of this form of monitoring in children are discussed.
متن کاملdomestication and foreignization in children literature translation
این پایان نامه به بررسی بومی سازی و بیگانه سازی در ادبیات کودکان مخصوصا زانر فانتزی می پردازد. در این پایان نامه ترجمه 14 کتاب داستان فانتزی برای سه گروه سنی کودکان بر اساس مدل ونوتی یعنی بومی سازی و بیگانه سازی مقاسه شدندکه در نتیجه برای سه گروه سنی از هر دو استراتزی توسط مترجمان در ترجمه کلمات فرهنگی استفاده شده است.
Improved accuracy of lactose tolerance test in children, using expired H2 measurement.
Expired hydrogen and blood glucose were measured during an oral lactose tolerance test in 163 children aged between 9 months and 14 years. Lactose malabsorption, defined as an abnormal increase in expired H2 during a lactose tolerance test, was found in 54 children. Of these, 30 were found to be lactose intolerant as the increased expired H2 was accompanied by clinical symptoms. The other 109 c...
متن کاملPreoxygenation using invasive ventilator in volume control mode in patients with emergency intubation can shorten the time of preoxygenation and improve the quality of preoxygenation
Preoxygenation can rapidly improve oxygenation and enhance the security of endotracheal intubation, so it is very essential before endotracheal intubation. The conventional preoxygenation method self-inflating bag (SIB) is not very effective in case of emergency. So our study aims to find a more effective method of preoxygenation in a critical situation.We retrospectively analyzed data of 105 p...
متن کاملDrawover anaesthesia and preoxygenation.
We have studied the efficacy of preoxygenation using the Triservice Anaesthetic Apparatus (TSA) in healthy patients and found it to be unsatisfactory. An alternative technique suitable for field use was explored. The Mapleson D system (Bain) was found to be suitable for preoxygenation with a fresh gas flow of only 4 litre of oxygen per minute. In a randomized study using only 4 litre of oxygen ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: British Journal of Anaesthesia
سال: 1996
ISSN: 0007-0912
DOI: 10.1093/bja/77.3.333