Preparation of Certified Reference Materials for Radioactivity Measurement Using Brown Rice

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trueness Assessment for Serum Glucose Measurement Using Commercial Systems through the Preparation of Commutable Reference Materials

BACKGROUND Commutable reference materials (RMs) are suitable for end-users for evaluating the metrological traceability of values obtained using routine measurement systems. We assessed the performance of 6 routine measurement systems with validated secondary RMs. METHODS We tested the homogeneity, stability, and commutability of 5 minimally processed human serum pools according to the standa...

متن کامل

Monte Carlo Simulation for the Evaluation of Measurement Uncertainty of Pharmaceutical Certified Reference Materials

O suplemento do Guia para a Expressão da Incerteza de Medição (GUM) publicado em 2008, o qual trata da propagação de distribuições, encoraja o uso do método de Monte Carlo (MC) para a estimativa de incerteza de medição. Este artigo descreve a aplicação deste método para estimativa da incerteza de medição do teor de ingredientes ativos farmacêuticos em dois novos materiais de referência certific...

متن کامل

Performance criteria for reference measurement procedures and reference materials.

The concept of metrological traceability of measurement results to property values assigned to measurement standards of higher metrological order or to the International System of Units (SI) through sequential calibrations, using reference materials and reference measurement procedures, plays a key role in ensuring that end user measurement procedures perform at an acceptable level in the clini...

متن کامل

IRMM-1000a and IRMM-1000b uranium reference materials certified for the production date. Part I: methodology, preparation and target characteristics

The paper describes the preparation and production of the reference materials, IRMM-1000a and IRMM-1000b, certified for the production date based on the 230Th/234U radiochronometer in compliance with ISO Guide 34:2009. The production date of the reference materials corresponds to the last separation of 230Th from 234U, i.e. when the initial daughter nuclide content in the material was finally r...

متن کامل

Preparation and characterization of candidate reference materials for telomerase assays.

BACKGROUND Telomerase has been measured in body fluids of cancer patients, and clinical tests for telomerase may have utility as noninvasive, cost-effective methods for the early detection of cancer. However, telomerase activity measured by common methods such as the telomerase repeat amplification protocol (TRAP) and telomerase reverse transcriptase catalytic subunit (hTERT) mRNA by reverse tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: RADIOISOTOPES

سال: 2016

ISSN: 0033-8303,1884-4111

DOI: 10.3769/radioisotopes.65.169