Pressure Measurement by Photoelectron Counting.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Methods for precise photoelectron counting with photomultipliers

A series of measurements has been performed on a THORN EMI 9351 phototube in order to investigate its response to a low light intensity. Precise procedures to determine the intensity of the incident photon #ux have been developed and compared. The data show that the various approaches give consistent and reliable results, thus allowing the precise calibration of the device for applications of p...

متن کامل

Photoelectron - Counting Distributions for Irradiance - Modulated Radiation

Photoelectron-counting distributions are obtained for modulated radiation sources, with arbitrary modulation waveforms and depths. Cases treated in detail include chaotic, amplitude-stabilized, and Risken sources, with square-wave, triangular, and sinusoidal modulation. Modulation is shown to broaden the counting distributions, an effect interpretable as accentuated photon bunching. The broaden...

متن کامل

Statistical method for resolving the photon-photoelectron-counting inversion problem

A statistical inversion method is proposed for the photon–photoelectron-counting statistics in quantum key distribution experiment. With the statistical viewpoint, this problem is equivalent to the parameter estimation for an infinite binomial mixture model. The coarse-graining idea and Bayesian methods are applied to deal with this ill-posed problem, which is a good simple example to show the ...

متن کامل

The measurement of cerebral blood flow by external isotope counting.

The Kety-Schmidt nitrous oxide method (2) is presently the only well-accepted technique for the quantitative estimation of human cerebral perfusion. In spite of theoretical objections (3) and practical limitations it has provided a wealth of otherwise unobtainable information. The procedure is tedious, however, and has remained predominantly a laboratory research tool. Efforts have continued to...

متن کامل

Measurement of the Neutron Lifetime by Counting Trapped Protons

We measured the neutron decay lifetime by counting in-beam neutron decay recoil protons trapped in a quasi-Penning trap. The absolute neutron beam fluence was measured by capture in a thin (6)LiF foil detector with known efficiency. The combination of these measurements gives the neutron lifetime: τ n = (886.8 ± 1.2 ± 3.2) s, where the first (second) uncertainty is statistical (systematic) in n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: SHINKU

سال: 1994

ISSN: 0559-8516,1880-9413

DOI: 10.3131/jvsj.37.714