Primary Hip Replacement with Cementless «ESI» Implants

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cementless total hip replacement complications.

early osteointegration. On-growth of bone to porous coated prostheses is influenced by many factors such as the composition and topography of the surface, as well as the local biological and mechanical environment in the immediately adjacent bone. Given that the short stem femoral implant is orientated in a more oblique to transverse trajectory, it might be subjected to greater bending moments ...

متن کامل

Pedestal sign in cementless total hip replacement.

Dear Editor, Stability of cementless hip components depends on the ingrowth of bone into porosities of the surface coating. However, clinical and radiographic examination of a stable total hip arthroplasty (ΤΗΑ) remains a challenge. The evaluation of a ΤΗΑ radiograph involves the recognition of various radiological signs that can indicate loosening of the implants. Amongst them is the Pedestal ...

متن کامل

Total hip replacement: A meta-analysis to evaluate survival of cemented, cementless and hybrid implants

AIM To determine whether cemented, cementless, or hybrid implant was superior to the other in terms of survival rate. METHODS Systematic searches across MEDLINE, CINAHL, and Cochrane that compared cemented, cementless and hybrid total hip replacement (THR) were performed. Two independent reviewers evaluated the risk ratios of revision due to any cause, aseptic loosening, infection, and disloc...

متن کامل

Zurich cementless total hip replacement: retrospective evaluation of 2nd generation implants in 60 dogs.

OBJECTIVE To evaluate the results of application, and identify complications, of the 2nd generation of Zurich Cementless Total Hip Replacement (ZCTHR). STUDY DESIGN Case series. ANIMALS Client-owned dogs (n=60) that had ZCTHR (n=65). METHODS Dogs with ZCTHR (2001-2003) with a minimum follow-up > or =6 months were evaluated. Data included signalment, cup position, longest follow-up, compli...

متن کامل

[Mid-term results of cementless ultima cups in primary total hip replacement].

PURPOSE OF THE STUDY To present the results of primary total hip arthroplasty (THA) with use of the hemispheric threaded Ultima cup at 8.5-year follow-up. MATERIAL Between 1996 and 1999, a total of 40 Ultima acetabular components were used in 33 patients (15 men and 18 women). The average age at the time of surgery was 61.2 years (range, 45 to 71). By the end of 2006, 36 cups were assessed. I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: N.N. Priorov Journal of Traumatology and Orthopedics

سال: 2009

ISSN: 2658-6738,0869-8678

DOI: 10.17816/vto200916314-20