Generation of pseudo-CT from a single MRI for PET/MR attenuation correction purposes
INSERM UMR 1101, LaTIM, Brest, France Current MR attenuation correction (AC) approaches suffer from the lack of precision in the detection of bone and the assigned attenuation coefficients. In general, no unique transformation of MR image intensities into attenuation coefficients exists. The purpose of this work is to derive attenuation coefficient maps from a single MR sequence through the gen...
متن کاملComparing 511 keV Attenuation Maps Obtained from Different Energy Mapping Methods for CT Based Attenuation Correction of PET Data
Introduction: The advent of dual-modality PET/CT scanners has revolutionized clinical oncology by improving lesion localization and facilitating treatment planning for radiotherapy. In addition, the use of CT images for CT-based attenuation correction (CTAC) decreases the overall scanning time and creates a noise-free attenuation map (6map). CTAC methods include scaling, s...
متن کاملA novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study
In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...
متن کاملCine CT for attenuation correction in cardiac PET/CT.
UNLABELLED In dual-modality PET/CT systems, the CT scan provides the attenuation map for PET attenuation correction. The current clinical practice of obtaining a single helical CT scan provides only a snapshot of the respiratory cycle, whereas PET occurs over multiple respiratory cycles. Misalignment of the attenuation map and emission image because of respiratory motion causes errors in the at...
متن کاملSPECT/CT physical principles and attenuation correction.
Using nuclear medicine techniques, physiologic activity and processes can be identified in a way that is unique from other modalities. Oftentimes it is helpful to know the exact location of the physiologic uptake that is visualized on a scan. Knowing the exact location can sometimes help to distinguish normal from abnormal physiologic uptake. When an abnormality has been identified, knowing the...