Processing and compression testing of Ti6Al4V foams for biomedical applications

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical performance of three-dimensional bio- nanocomposite scaffolds designed with digital light processing for biomedical applications

Introduction: The need for biocompatible and bioactive scaffolds to accelerate the regeneration and repair of fractured bones has been considered for bone tissue engineering applications during recent decades. The new methods were developed to produce scaffolds to improve the tissue quality, size of cavities, control the porosity and increase the scaffold compressive strength u...

متن کامل

simulation and design of electronic processing circuit for restaurants e-procurement system

the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...

15 صفحه اول

Study of the compression and wear-resistance properties of freeze-cast Ti and Ti‒5W alloy foams for biomedical applications.

Ti and Ti‒5wt% W alloy foams were produced by freeze-casting process and their mechanical behaviors were compared. The Ti‒5W alloy foam showed a typical acicular Widmanstätten α/β structure with most of the W dissolved in the β phase. An electron-probe microanalysis revealed that approximately 2wt% W was uniformly dissolved in the Ti matrix of Ti‒5W alloy foam with few partially dissolved W par...

متن کامل

Loading Drug on Nanostructured Ti6Al4V-HA for Implant Applications

Arrayed Ti6Al4V nanotubes (TNT) coated with hydroxyapatite (HA) were synthesized via electrochemical anodization method. Paracetamol was loaded onto TNT-HA electrode. Effects of anodization, nanotube formation and hydroxyapatite deposition on sorption and release of the drug were investigated. Saturation time of paracetamol on the anodized samples was 30% shorter than the hydroxyapatite-coated ...

متن کامل

Biomedical Signal Processing and Applications

In biomedical signal processing, the aim is to extract clinically, biochemically or pharmaceutically relevant information in order to enable an improved medical diagnosis. All living things, from cells to organism, deliver signals of biological origin. Such signals can be electric, mechanical, or chemical. All such signals can be of interest for diagnosis, for patient monitoring and biomedical ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Materials Science

سال: 2009

ISSN: 0022-2461,1573-4803

DOI: 10.1007/s10853-008-3038-7