Processing Efficiency, Simulation and Enzyme Activities Analysis of an Air-Lift Multilevel Circulation Membrane Bioreactor (AMCMBR) on Marine Domestic Sewage Treatment
نویسندگان
چکیده
منابع مشابه
Copper Recovery from Chalcopyrite Concentrate by an Indigenous Acidithiobacillus ferrooxidans in an Air-Lift Bioreactor
In this study, effects of solid concentration, temperature, and initial Fe2+ concentration on bioleaching of sulfide mineral (chalcopyrite) obtained from Sarcheshmeh Copper Mine in the region of Kerman located in the south of Iran were investigated. A mesophilic iron oxidizing bacterium, Acidithiobacillus ferrooxidans has been isolated from a typical chalcopyrite copper concentra...
متن کاملStudy on Anaerobic/Aerobic Membrane Bioreactor Treatment for Domestic Wastewater
A 69-day experimental study was conducted to investigate the treatment process of municipal wastewater using submerged membrane bioreactor technology. The results show that the average removal rate of COD and BOD5 were over 90%. The removal rate of NH3-N was 99% and the concentration of effluent NH3-N was below 0.5mg/L; because of the high DO value in the denitration sect, the denitrobacteria w...
متن کاملDevelopment of Membrane Bioreactor to Membrane Electro-bioreactor for Advanced Treatment of Wastewater
Limited available water resources have rendered wastewater reuse an important issue to specialists in most developed countries, today. The current study works on membrane filtration for treatment of industrial wastewater. By comparing the two methods of membrane bioreactor (MBR) and hybrid membrane electro bioreactor (MEBR) processes, it finds that earlier fouling in the membrane occurs in the ...
متن کاملAnaerobic membrane bioreactor (AnMBR) for domestic wastewater treatment
The effect of backwash frequency (15, 30 and 60 min) and influent flux (3.75, 7.50 and 11.25 L/h/m) on fouling amelioration in an innovative external side-stream dead-end microfiltration anaerobic membrane bioreactor (AnMBR) for the treatment of domestic wastewater at 25EC was investigated. During 6 months of reactor operation, a constant COD removal of 88% and an accumulation of 350 mg TSS/L/d...
متن کاملDevelopment of Membrane Bioreactor to Membrane Electro-bioreactor for Advanced Treatment of Wastewater
Limited available water resources have rendered wastewater reuse an important issue to specialists in most developed countries, today. The current study works on membrane filtration for treatment of industrial wastewater. By comparing the two methods of membrane bioreactor (MBR) and hybrid membrane electro bioreactor (MEBR) processes, it finds that earlier fouling in the membrane occurs in the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Periodica Polytechnica Chemical Engineering
سال: 2019
ISSN: 1587-3765,0324-5853
DOI: 10.3311/ppch.13389