Proportional-Resonant Control of Doubly-Fed Induction Generator Wind Turbines for Low-Voltage Ride-Through Enhancement

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proportional-Resonant Control of Doubly-Fed Induction Generator Wind Turbines for Low-Voltage Ride-Through Enhancement

A novel control strategy is proposed in this paper for the rotor side converter (RSC) of doubly-fed induction generator (DFIG)-based wind power generation systems. It is supposed to enhance the low-voltage ride-through (LVRT) capability of DFIGs during great-level grid voltage dips. The strategy consists of a proportional-resonant (PR) controller and auxiliary PR controllers. The auxiliary cont...

متن کامل

High Voltage Ride Through with FACTS for Wind Turbines with Doubly Fed Induction Generator

In future grid codes wind farms will have to fulfill demanding fault ride through requirements. Among several grid faults the voltage swell is a critical event. Wind farms with doubly-fed induction generators will not be able to fulfill the new grid code requirements without additional fault mitigation equipment. In this publication the applicability of the Dynamic Voltage Restorer and the Stat...

متن کامل

Low Voltage Ride-Through Capability Improvement of Doubly Fed Induction Generator using DVR and SMES

Abstract: With the growth of communities and the increasing need for electricity, and because of the many benefits of renewable energy sources, the wind turbine has become a completely commercial and inevitable process, with increasing penetration into the electricity grid. Distribution networks, on the other hand, are subject to fault that cause power fluctuations and outflow of wind units. In...

متن کامل

Low voltage ride through of doubly-fed induction generator connected to the grid using sliding mode control strategy

Wind Energy Conversion System (WECS) based on Doubly Fed Induction Generator (DFIG) connected to the grid is subjected to high transient currents at rotor side and rise in DC-link voltage during voltage sag at stator/grid side. To secure power system operation wind turbines have to meet grid requirements through the Low voltage ride through (LVRT) capability and contribute to grid voltage contr...

متن کامل

Adaptive Backstepping Control for Wind Turbines with Doubly-fed Induction Generator under Unknown Parameters

This paper deals with an adaptive, nonlinear controller for wind systems connected to a stable electrical grid and using a doubly-fed induction machine as a generator. The study focuses on the case wherein the aerodynamic torque model and winding resistances of the generator are unknown and will be updating in real time. Two objectives were fixed; the first one is speed control, which allows us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2012

ISSN: 1996-1073

DOI: 10.3390/en5114758