Quantitative Analysis of Electron Microcopy Data
نویسندگان
چکیده
منابع مشابه
Quantitative nanoparticle structures from electron crystallography data
Christopher L. Farrow,1 Chong-Yu Ruan,2 and Simon J. L. Billinge1,3,* 1Department of Applied Physics and Applied Mathematics, Columbia University, New York, New York 10027, USA 2Department of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824, USA 3Condensed Matter Physics and Materials Science Department, Brookhaven National Laboratory, Upton, New York 11973, USA Re...
متن کاملMarginal Analysis of A Population-Based Genetic Association Study of Quantitative Traits with Incomplete Longitudinal Data
A common study to investigate gene-environment interaction is designed to be longitudinal and population-based. Data arising from longitudinal association studies often contain missing responses. Naive analysis without taking missingness into account may produce invalid inference, especially when the missing data mechanism depends on the response process. To address this issue in the ana...
متن کاملPhotomarking Relocalization Technique for Correlated Two-Photon and Electron Microcopy Imaging of Single Stimulated Synapses.
Synapses learn and remember by persistent modifications of their internal structures and composition but, due to their small size, it is difficult to observe these changes at the ultrastructural level in real time. Two-photon fluorescence microscopy (2PM) allows time-course live imaging of individual synapses but lacks ultrastructural resolution. Electron microscopy (EM) allows the ultrastructu...
متن کاملQuantitative phase analysis in electron holographic interferometry.
Holographic interferometry in an electron microscope and its phase analysis technique are described. The fringe scanning method is used to gain high sensitivity in phase detection. An example of measuring a magnetic field of a fine particle is presented. The measurement accuracy for median filtering is about 1/70 fringe corresponding to the magnetic flux sensitivity of 6 x 10(-17) Wb. Noise red...
متن کاملDistortion Correction in Scanning Transmission Electron Microcopy with Controllable Scanning Pathways
Quantitative intensity and distance measurements in atomically resolved scanning transmission electron microscopy (STEM) imaging relies on the precision of the intensity and position of the images corresponding to the scanned sample area. Conventional STEM rastering modes are limited by drift distortion in the slow scan direction. It has been realized that the scan direction is a parameter that...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Materia Japan
سال: 2019
ISSN: 1340-2625,1884-5843
DOI: 10.2320/materia.58.68