Quantitative analysis of PbO-SiO2 glass by electron microprobe (Technical Report)

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative electron microprobe analysis of homogeneous bulk samples

where Q*i is the cross section per atom for ionization of the selected subshell of the i element, taking into account both direct ionization by the electrons of energy E and the effect of indirect ionizations at that subshell caused by the Coster-Kronig transitions. N, ρ, t and N are Avogadro's number, the density and thickness of a very thin tracer layer made of the i element and the number of...

متن کامل

Electron Microprobe Analysis in Guided Tissue Regeneration: A Case Report

OBJECTIVES Several procedures have been advocated as regenerative procedures in periodontology, but one of the most widely used techniques up to now is guided tissue regeneration (GTR). Likewise, different assessment methods based on clinical, radiographic or histological measurements have been proposed for the evaluation of these regenerative procedures. However, none of the methods used for h...

متن کامل

Electron Microprobe Analysis Lecture Notes

The electron microprobe provides a complete micrometer-scale quantitative chemical analysis of inorganic solids. The method is nondestructive and utilizes characteristic Xrays excited by an electron beam incident on a flat surface of the sample. This course provides an introduction to the theory of X-ray microanalysis through wavelength and energy dispersive spectrometry (WDS and EDS), ZAF matr...

متن کامل

Electron microprobe analysis of lunar samples.

Plagioclase feldspar, clinopyroxene, and ilmenite in a polished thin section of a type A crystalline rock were analyzed. The clinopyroxene grains are compositionally variable, and both high Ca and low Ca phases are present. The plagioclase is compositionally homogeneous. The ilmenite is chemically homogeneous except for occasional, small areas of high local chromium concentration. Accessory min...

متن کامل

Minimizing Errors in Electron Microprobe Analysis.

Errors in quantitative electron microprobe analysis arise from many sources including those associated with sampling, specimen preparation, instrument operation, data collection, and analysis. The relative magnitudes of some of these factors are assessed for a sample of NiAl used to demonstrate important concerns in the analysis of even a relatively simple system measured under standard operati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Pure and Applied Chemistry

سال: 1996

ISSN: 1365-3075,0033-4545

DOI: 10.1351/pac199668081657