Quantitative contrast-enhanced first-pass cardiac perfusion MRI at 3 tesla with accurate arterial input function and myocardial wall enhancement
نویسندگان
چکیده
منابع مشابه
First-pass myocardial perfusion cardiovascular magnetic resonance at 3 Tesla.
PURPOSE To test the feasibility of first-pass contrast-enhanced myocardial perfusion imaging at 3 Tesla and to evaluate the change in perfusion index between normal, remote and ischemic myocardium, we obtained perfusion index from healthy subjects and patients with coronary artery stenosis. MATERIALS AND METHODS First-pass contrast-enhanced perfusion imaging was performed on 12 patients and 3...
متن کاملQuantitative myocardial perfusion analysis with a dual-bolus contrast-enhanced first-pass MRI technique in humans.
PURPOSE To compare fully quantitative and semiquantitative analysis of rest and stress myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) using a dual-bolus first-pass perfusion MRI method in humans. MATERIALS AND METHODS Rest and dipyridamole stress perfusion imaging was performed on 10 healthy humans by administering gadolinium contrast using a dual-bolus protocol. Ventricul...
متن کاملQuantitative 3D Myocardial Perfusion Imaging at High Dose with Accurate Arterial Input Function Assessment
Quantitative 3D Myocardial Perfusion Imaging at High Dose with Accurate Arterial Input Function Assessment Lukas Wissmann, Markus Niemann, Robert Manka, and Sebastian Kozerke Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland, Department of Cardiology, University Hospital Zurich, Zurich, Switzerland, Division of Imaging Sciences & Biomedical Engineering, King's...
متن کاملFirst-Pass Contrast-Enhanced Myocardial Perfusion MRI in Mice on a 3-T Clinical MR Scanner
First-pass contrast-enhanced myocardial perfusion MRI in rodents has so far not been possible due to the temporal and spatial resolution requirements. We developed a new first-pass perfusion MR method for rodent imaging on a clinical 3.0-T scanner (Philips Healthcare, Best, The Netherlands) that employed 10-fold k-space and time domain undersampling with constrained image reconstruction, using ...
متن کاملQuantitative Perfusion Analysis of First-Pass Contrast Enhancement Kinetics: Application to MRI of Myocardial Perfusion in Coronary Artery Disease
PURPOSE Perfusion analysis from first-pass contrast enhancement kinetics requires modeling tissue contrast exchange. This study presents a new approach for numerical implementation of the tissue homogeneity model, incorporating flexible distance steps along the capillary (NTHf). METHODS The proposed NTHf model considers contrast exchange in fluid packets flowing along the capillary, incorpora...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Magnetic Resonance Imaging
سال: 2011
ISSN: 1053-1807
DOI: 10.1002/jmri.22647