Quantitative Amyloid Imaging Using Image-Derived Arterial Input Function

Amyloid PET imaging is an indispensable tool widely used in the investigation, diagnosis and monitoring of Alzheimer's disease (AD). Currently, a reference region based approach is used as the mainstream quantification technique for amyloid imaging. This approach assumes the reference region is amyloid free and has the same tracer influx and washout kinetics as the regions of interest. However,...

متن کامل

Quantitative myocardial perfusion imaging using a step arterial-input function

Background Modern MRI myocardial perfusion protocols use rapid venous bolus injections, typically 3-5 ml/s of 5-15 ml of agent over a few seconds. The resulting arterial input functions are rapidly varying with high agent concentrations (Fig. 1A and 1B) and thus typically require high temporal resolution acquisitions (~1 sec), custom pulse sequences and complex processing methods for perfusion ...

متن کامل

Image-Derived Input Function for Human Brain Using High Resolution PET Imaging with [11C](R)-rolipram and [11C]PBR28

BACKGROUND The aim of this study was to test seven previously published image-input methods in state-of-the-art high resolution PET brain images. Images were obtained with a High Resolution Research Tomograph plus a resolution-recovery reconstruction algorithm using two different radioligands with different radiometabolite fractions. Three of the methods required arterial blood samples to scale...

متن کامل

Quantification of brain glucose metabolism by 18F-FDG PET with real-time arterial and image-derived input function in mice.

UNLABELLED Kinetic modeling of PET data derived from mouse models remains hampered by the technical inaccessibility of an accurate input function (IF). In this work, we tested the feasibility of IF measurement with an arteriovenous shunt and a coincidence counter in mice and compared the method with an image-derived IF (IDIF) obtained by ensemble-learning independent component analysis of the h...

متن کامل

Fully automated calculation of image-derived input function in simultaneous PET/MRI in a sheep model

BACKGROUND Obtaining the arterial input function (AIF) from image data in dynamic positron emission tomography (PET) examinations is a non-invasive alternative to arterial blood sampling. In simultaneous PET/magnetic resonance imaging (PET/MRI), high-resolution MRI angiographies can be used to define major arteries for correction of partial-volume effects (PVE) and point spread function (PSF) r...