Quantitative material characterization from multi-energy photon counting CT.
PURPOSE To quantify the concentration of soft-tissue components of water, fat, and calcium through the decomposition of the x-ray spectral signatures in multi-energy CT images. METHODS Decomposition of dual-energy and multi-energy x-ray data into basis materials can be performed in the projection domain, image domain, or during image reconstruction. In this work, the authors present methodolo...
متن کاملCalibration methods influence quantitative material decomposition in photon-counting spectral CT
Photon-counting detectors and nanoparticle contrast agents can potentially enable molecular imaging and material decomposition in computed tomography (CT). Material decomposition has been investigated using both simulated and acquired data sets. However, the effect of calibration methods on material decomposition has not been systematically investigated. Therefore, the objective of this study w...
متن کاملExperimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical CT
Theoretical considerations predicted the feasibility of K-edge x-ray computed tomography (CT) imaging using energy discriminating detectors with more than two energy bins. This technique enables material-specific imaging in CT, which in combination with high-Z element based contrast agents, opens up possibilities for new medical applications. In this paper, we present a CT system with energy de...
متن کاملStatistical analysis of Multi-Material Components using Dual Energy CT
This work describes a novel method for statistical analysis of multi-material components. The application scenario is industrial 3D X-ray computed tomography, emphasizing metrology of artefact affected plastics-metal components. The presented work makes use of dual energy CT data acquisition for artefact reduction, in order to optimize CT scans of multi-material components. Using statistical an...
متن کاملGuided Noise Reduction for Spectral CT with Energy-Selective Photon Counting Detectors
We investigate the use of joint bilateral filtering for noise reduction in energy-selective photon counting detectors. A guidance image from all energy channels is computed, which steers a non-linear filter to denoise each energy bin individually. Our novel approach is evaluated with cone beam data simulated using a numerical cardiac phantom. Results indicate that the method increases cross-tal...